Appendix -2
1.1
Profile
R
D
C
T
6.5
7
ENTER
5
2
SHIFT
0
1
4
M
S
Y
A
W
E
3
6
ADR / DOC
CV / PV
DEC / HEX
B
F
CLEAR
8
7
X
+
9
ON / OFF
FUN
7
9.9
14.75
22.43
DATA ACCESS PANEL
12
102.5
4.75
8
1.5
16
118.45
148
98
112
148
30
17.6
外徑
4
ψ×
4
埋螺帽
14.8
Ba
ck
Fro
nt
FB-DAP
FATEK
La
te
ra
l
1.2
Important points before operation
1
、
FB-DAP possesses a function to return to the operation mode (general data setter and self-definition 8/16
speed keys) before power failure and each DAP can be place in a different mode when connecting many sets.
2
、
When operating FB-DAP
,
D2944
~
D3071 register of PLC will be used as the systematic architecture zone (in
which data set by all the FUN functions can be stored except item 11) , the user shall avoid this zone.
3
、
Any communication port, once converted to a RS-485 interface (port 2 is itself a RS-485 interface), can be
connected to a maximum of 16 FB-DAP-B(R) sets.
B
FB-485P0 switch head
B
RS-485 interface
B
FB-485 switch
B
RS-485 interface
Only thus so the FB-DAPB (R) can
be connected to.
PLC port0
(HCMOS)
PLC port1
(RS-232)
4
、
When PLC is connected with FB-DAP-B(R)
,
the service point numbers of PLC are limited to a range of 1~32.
5
、
Parameters for the connection between PLC and FB-DAP-B(R)(DAP automatic detection Baud Rate 9600 /
19200 / 38400)
port0
、
1
、
2
:
9600 / 19200 / 38400
、
Even
、
7Data bits
、
1Stop bit
ex
:
R4158=5521H, i.e. port2 being 9600
;
R4158=5523H, i.e. port2 being 38400.
6
、
When many sets of DAP are connected, if any two or more have the same service point number, then DAP will
request for number change, which can be done by only entering
〝
new DAP
〞即可。
7
、
The transmission line of the RS-485 interface must use a twisted pair with a shielded cover on the outer layer.
Please refer to chapter 12-5 in the Operation Manual II for other important points.
8
、
The scanning time of PLC will affect the update time of DAP.
9
、
The OS of FB-DAPB(R) shall be new V2.00 above PCB so that multiple sets can be connected. Press
then the OS version is displayed.
10
、
When PROLADDER(or FP07) and DAP are connected to the same set of PLC, to change the program
through PROLADDER is not allowed; if so, the timer information displayed by DAP won’t be correct (In this