![FATEK FBs Series Manual Download Page 315](http://html1.mh-extra.com/html/fatek/fbs-series/fbs-series_manual_3764826315.webp)
8 -10
●
STPEND :
(
Displayed in WinProladder
)
or
STPEND
:
(
Displayed in FP-07
)
This instruction represents the end of a process. It is necessary to include this instruction so all processes can be
operated correctly.
A PLC can have up to 8 step processes (S0
~
S7) and is able to control them simultaneously. Therefore, up to 8
STPEND instructions can be obtained.
【
Example
】
WinProladder
FP-07
M1924
STPEND
M1924
STPEND
STPEND
M1924
STP S1
STP S0
STP S7
M1924
STPEND
STP S0
TO S0
STPEND
M1924
M1924
STPEND
TO S1
STP S1
TO S7
STP S7
ORG
TO
STP
˙
˙
˙
STPEND
ORG
TO
STP
˙
˙
˙
STPEND
ORG
TO
STP
˙
˙
˙
STPEND
M1924
S0
S0
M1924
S1
S1
M1924
S7
S7
【
Description
】
When ON, the 8 step processes will be active simultaneously.