![FATEK FBs Series Manual Download Page 322](http://html1.mh-extra.com/html/fatek/fbs-series/fbs-series_manual_3764826322.webp)
8 -17
Example 2
Liquid Stirring Process
Weighing
Dried
material
Empty Limit
Switch
X1
Value 1 Y5
CH0 : R3840
Value 1 Y6
Liquid
Value Y7
Stirring Unit
Value Y9
No Liquid Limit
Switch
X2
Value 4 Y10
Clear Water
Finished Product
Outlet
Stirring
Motor
Y8
Electromagnetic Switch
X4
Overload Switch
Input Points: Empty limit switch X1
No liquid limit switch X2
Empty limit switch X3
Over-load switch X4
Warning clear button X5
Start button X6
Water washing button X7
Warning Indicators: Empty dried material Y1
Insufficient liquid Y2
Empty stirring unit Y3
Motor over-load Y4
Output Points: Dried material inlet valve Y5
Dried material inlet valve Y6
Liquid inlet valve Y7
Motor start electromagnetic valve Y8
Clean water inlet valve Y9
Finished product outlet valve Y10
Weighing Output: CH0
(
R3840
)
M1918=0
Clean Water