Advanced Function Instruction
7 -11 8
FUN142
P
PSOFF
STOP THE HSPSO PULSE OUTPUT
(Brief description on function)
FUN142
P
PSOFF
Ps : 0
~
3
Enforce the Pulse Output PSOn (n= Ps) to stop.
Command descriptions
z
When execution control “EN” =1 or “EN
↑
” (
P
instruction) changes from 0
→
1, this instruction will enforce
the assigned number set of HSPSO (High Speed Pulse Output) to stop pulse output.
z
While in the application for mechanical original point reset, as soon as reach the original point can use this
instruction to stop the pulse output immediately, so as to make the original point stop at the same position
every time when performing mechanical original point resetting.
z
For detailed functional description and usage, please refer to chapter 13 “The NC positioning control of
FBs-PLC” for explanation.