-57-
7.5 Operating by I/O signals
7.5.1 Operating
The motor can be operated and stopped from the external signals.
Set and operate as follows after operation input (FWD input, REV input) connect to CN4.
• Setting the “External operation signal input” parameter
The “External operation signal input” parameter (Par -> ioEn -> on / oFF) is required to change
the setting when operating or stopping the motor externally. The factory setting is “OFF”
When “The “External operation signal input” parameter is ON, External I / O control is enabled,
but the front control of the drive is disabled. When “The “External operation signal input”
parameter is OFF, External I / O control is disable, but the front control of the drive is enabled.
Power ON
Setting to the external operation
Operation signals
Motor rotates
Motor deceleration stop
Change the “External operation signal
input” parameter
Turn the FWD or REV input ON.
Operation input change from ON to OFF
I/O signal operation
Motor
Drive
I/O Signal
AC power input
Summary of Contents for Ezi-SPEED ESD-30-C
Page 1: ......
Page 9: ...9 2 Characteristics 2 1 Part number...
Page 15: ...15 3 2 Dimensions 30W 60W 120W Drive 200W 400W Drive...
Page 18: ...18 ESM 90 H 120 ESM 104 H 200 ESM 104 H 400...
Page 19: ...19 4 3 Characteristics of motor torque 30W 60W 120W...
Page 20: ...20 200W 400W...
Page 63: ...63 8 2 Setting and 7 segments display 1 Monitor mode...
Page 64: ...64 2 Input Output setting mode...
Page 65: ...65 3 Parameter setting mode 1page...
Page 66: ...66 3 Parameter setting mode 2page...
Page 67: ...67 3 Parameter setting mode 3page...
Page 68: ...68 3 Parameter setting mode 4page...
Page 69: ...69 4 NVM saving mode...