When the Freeze
r Closed Switch has been detected, Control will advance to a “Clean
-
up” state
before returning to the “Idle” state to await another vend request.
E.
Cleanup
The “Clean
-
Up” state issues the “Vend Success” or “Vend Failure” signal to the Executive portion of
the DIVI firmware. Control resets all parameters to prepare for the next vend request. Motors and
switches are inspected. If the Vacuum Pump has returned to the garage, if the Z Home Switch is
active, if the Robot Arm is at the delivery point and if no errors have been reported then Control will
return to the “Idle” state.
37.
APPENDIX
DIVI Lid Lift Mechanism Replacement and Installation Instructions
Necessary Tools and Accessory Items:
¼” wrench;
3/8” wrench;
5/16” wrench;
cutting pliers;
(8) Cable Ties – 7-½”
38.
The Fastcorp DIVI Lid Lift Mechanism
can be removed and replaced in approximately 30 to 45 minutes.
A.
Locate the power switch on the left side of the Power Supply under the delivery bin and turn it “OFF” to remove
power to the VMC Board and the Freezer Lid Lift Mechanism.
B.
Reach down behind the freezer to unplug the 2 pin connector for the circulation fan.
C.
Reach behind the freezer (right rear corner) to unplug the 2 pin thermistor connector. The harness will be labeled,
“freezer”. Be careful of sharp edges inside the cabinet.
D.
Remove the cover from the Freezer Closed Switch Assembly (right front corner of Freezer). Make note of how the
harness is plugged into the switch (common and normally open) and then unplug the switch.
E.
Note how the Freezer Lid Lift Harness is routed and where the cable ties are positioned. Mark each location on the
cabinet and the harness. Follow the harness to the VMC Board and disconnect the connector at J3.
F.
Carefully cut and remove the cable ties that hold the harness in place.
G.
Manually open the Freezer Lid to access and remove the two (2) Freezer Lid Lift Mechanism retaining screws using a
3/8” wrench. These screws will be used over again to install the new mechanism.
H.
If machine is equipped with fuse block for the lid lift, remove wires identified for the lid lift in the fuse identification
table, by using a 3-4mm flat screw driver and insert in the fuse block wire port to release the wire, if this is not available, you
can cut and wire nut the wires to the new harness.