Fastcorp, LLC
DIVI Setup and Users Guide
Page
43
of
62
Rev 6
Press the pound (#) key to enter the selection. The Display will read, “
Programming
”. An
LED status light on the right side of the VMC Board will start flashing rapidly. When the
process is complete, the display will read, “
UPDATE SUCCESS. Remove card…
”
To remove the Micro SD card, press down on the top. It should slide up slightly allowing
you to grasp it between your fingers. Lift the SD card straight up and out.
Notes -
Power does NOT have to be turned OFF to remove the SD card.
The vacuum may produce a clicking sound during this procedure. This is normal and is not a
concern.
A major firmware upgrade may require the Robot Arm to be re-calibrated. Please refer to the
section, “Calibrating the Robot Arm” in your manual. Scroll to Service Menu Option “4) Create
Selection”, Press “#” and follow the prompts to calibrate the Robot Arm.
Your programming data should have been saved to your Micro SD card and automatically
reinstalled with the program upgrade. Test vend selections to confirm accuracy. Go to Service
Menu 22) Verify Bins to check accuracy and make adjustments if necessary.
If your bin configuration had not been saved, reinsert your Micro SD card into the
Daughter Board slot.
Press1 to Load Config.
Choose the name that you used to save your bin configuration.
Test-vend selections to confirm accuracy. Go to Service Menu 22) Verify Bins to check
accuracy and make adjustments if necessary.
36.
Robot Control Sequence / Order of Operations
Control of the Robot Arm and the Freezer proceed through a sequence of states during the course of the vend cycle
and until the product is delivered. These states are detailed below:
A.
Idle State:
The Robot Arm is at the delivery position with the freezer closed.
B.
Vend Cycle Begins:
Money is inserted into the machine and a selection is made. A credit is established and Control
issues a request to convert a selection number into a product location.
The Freezer Open Switch and Freezer Closed Switch circuits are inspected. If both circuits are active,
an error is declared. Otherwise, Control issues a request to open the Freezer. A seven second timer
is set and Control proceeds to the “Freezer Open” state.