FASTER TM T– Issue 00
27
FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI) – tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: [email protected]
E
N
G
L
I
S
H
-
Defrost interval:
set the defrost interval in hours - i.e. the time between one defrost cycle and the next. This
value can be varied from 1h and 8h and is pre-set at 4h.
.
Refrigerator safety action delay:
sets the delay time for refrigerator safety activation This period of time
prevents the vending machine from shutting down following an operation that involves having the door open
with the subsequent increase in the internal temperature. The delay in activating the refrigeration unit safety
device gives the machine time to return to its normal operating temperature. The value of this command is
pre-set at 60 min. but can be varied from 30 to 360 min.
Refrigerator safety temperature:
sets the trigger temperature for the safety device, that is the temperature
above which it prevents the machine from vending the selected product
.
This control is disabled when the
machine is switched on and after the door is shut for the period of time set in
Refrigerator safety action
delay
. The pre-set value is +7°C but it can be changed b7°C and +35°C. When the refrigeration unit
safety device trips, the selections involved remain out of service. To reset the refrigeration unit safety device:
with the door open, access programming mode and reset the error using the
Cancel errors
icon
Products must be introduced at the correct temperature for preservation as specified by the
regulations in force. Non-observance of this regulation could activate the “refrigeration
safety device".
see paragraph “GUIDELINES FOR LOADING PRODUCTS”