FASTER TM T– Issue 00
25
FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI) – tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: [email protected]
E
N
G
L
I
S
H
-
¾
Automatic credit delivery
: in this case, the machine must be set to single-sale be set (for an
executive protocol payment system, single-sale must also be set in the payment system).
¾
Quarter turn
: if the product is not delivered the spiral completes a further 1/4 turn and if the product
has still not been delivered then the machine reverts to one of the preceding two options depending
on the single or multi-sale parameter that has been set.
•
For this purpose, once this mode has been set, the option is disabled by default for all selections.
In order to enable the single spiral option, select the
Selection management
icon and
then the
Photocells
icon.
The option is not applicable to ½ turn spirals. If the payment
system uses an Executive protocol, the single/multi-sale must also be set in the payment system.
Alternatively, it is possible to enable/disable the function for each drawer or directly for all
selections.
¾
Multistep
(multiple partial rotations): if the product is not delivered, the spiral will execute a further
1/8 turn and this will be repeated 4 times if the product is not delivered; on the fifth attempt, the spiral
will complete the turn and a product delivery check will be performed, after which one of the options
Select another product
or
Automatic credit delivery
will be triggered depending on whether the
single or multi-sale parameter has been set.
Also in this case, the function must be enabled for each selection, drawer or total (see previous
point).
The system then makes it possible to set the "empty" option which, if enabled, blocks the selection until the
next opening of the main door, in the event of failure to deliver the product.
The system then asks you to enter the options relevant to the PHOTOCELL SAFETY:
enabling this feature involves entering a number of products within a time window (in minutes). If within the
programmed time interval a number of non-readings occurs that is equal to the number of programmed
products, the photocells are disabled. The active event is signalled on the display when the door is opened
and is also recorded under
Error code 39. The photocell reset can be programmed in manual mode
or automatically by ticking the
Auto-reset
box. In automatic mode (box ticked), after 15 minutes the system
attempts to reset the function.
Calibration:
This command is for checking that the photocells are working properly.
When the type of test to run has been selected, a test procedure is started automatically; the result is
displayed on completion.. If there is a problem with the functioning, a second value appears on the display
which refers to the problem
.
Calibration:
starts the photocell calibration procedure by optimizing the light emitted by photodiodes
Test:
verifies calibration
Read test:
performs a physical read test
Exit
Calibration
Test
Read test
Ripple