background image

 

FASTER TM T– Issue 00 

FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI) – tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: [email protected]

E
N

G

L

S
H

Complete identification plate 

B Identification 

plate 

Safety sticker indicating danger from rotating parts 

Safety sticker indicating surfaces at high temperatures 

Safety sticker indicating voltage supplied 

Disposal in compliance with EU 2002/96/CE standards, according to the 
implementation of the Directive into the national law. 

(LED LIGHTING)  LASER RADIATION - DO NOT STARE INTO BEAM - CLASS 2 
LASER PRODUCT 

The complete identification plate "A", which states all the machine data, is located inside the cabinet (see 
diagram below). If there are any engraved details on the side of the cabinet, plate "B" is affixed to the rear of 
the cabinet, in the top right corner. 
Furthermore, the serial number is also printed on the most important element of the machine (fans, 
compressor cards, etc…). 

Summary of Contents for FASTER TMT

Page 1: ...DURE 14 6 1 TRANSPORT AND STORAGE 14 6 2 UNPACKING PROCEDURE 14 6 3 INSTALLATION 15 6 4 WARNINGS FOR THE INSTALLATION 16 6 5 PAYMENT SYSTEM CONNECTION 16 7 WARNINGS FOR THE DEMOLITION OF THE MACHINE 16 8 OPERATION ON THE MACHINE 17 8 1 PRODUCT LOADING PROCEDURE FOOD ZONE 17 8 1 1 GUIDELINES FOR LOADING PRODUCTS 17 8 2 SPACER FOR PRODUCTS ON FOOD ZONE 18 8 3 PRODUCT EXPELLER 18 8 4 VENDING A PRODUC...

Page 2: ...RROR CODE TABLE 55 11 ADJUSTMENTS 56 11 1 SPIRALS 56 11 2 PROCEDURE FOR REPLACING SPIRALS AND EXPELLER MOTOR GROUP 56 11 3 PROCEDURE FOR REMOVING THE DRAWERS 57 11 4 MODIFYING THE DRAWER NUMBER 57 11 5 PROCEDURE FOR CHANGING THE TEMPERATURE MANAGEMENT SIDE PANEL 58 11 6 FITTINGS FOR FASTENING DRAWER WIRING 59 11 7 INSTRUCTIONS FOR CONVERTING THE DRAWERS 60 11 8 ACCESS TO THE ELECTRIC PANEL AND REF...

Page 3: ...act working procedure The manual or a copy thereof must always be kept close to the machine for consultation by the operator it should be kept away from heat damp and corrosive agents oil lubricants corrosive products When consulting the manual ensure that it is not damaged do not remove the pages replace or delete the information or modify its contents in any way Any revisions and pages illustrat...

Page 4: ...Disposal in compliance with EU 2002 96 CE standards according to the implementation of the Directive into the national law H LED LIGHTING LASER RADIATION DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT The complete identification plate A which states all the machine data is located inside the cabinet see diagram below If there are any engraved details on the side of the cabinet plate B is affixed to ...

Page 5: ...in which the machine is used avoid wearing baggy or loose clothing belts rings and chains long hair must be kept under a suitable cap It is strictly prohibited to operate the machine with the fixed and or mobile protections disassembled or with the safety devices switched off It is strictly prohibited to remove or tamper with the safety devices Do not perform machine maintenance operations or adju...

Page 6: ...ne the terms at the front or front indicate the door side while the terms at the back or rear indicate the other side the terms right and left refer to the operator facing the front of the machine For each operation to be carried out on the machine a level of expertise see below is given to indicate the persons qualified to perform the operation concerned Final user Person without specific experti...

Page 7: ...Vico 60 SCHIO VI tel 39 0445 502011 fax 39 0445 502010 e mail info fas it E N G L I S H Failure to respect the number of personnel or the level of expertise specified can endanger the safety of the persons involved or those found in the vicinity of the machine ...

Page 8: ...g machine in accordance with the laws in force during transportation to the vending machine to maintain the products at the temperatures provided for by the laws in force This vending machine is equipped with a refrigeration safety device in accordance with the standards relevant to the preservation of fresh food in force in various countries which permits these products to be maintained in the co...

Page 9: ...A 310 kg FASTER 1050 SA T A Rated Voltage see identification plate Rated power see identification plate Ambient working conditions limit Max environmental temperature 32 C Min environmental temperature 3 C Relative humidity 65 max Refrigeration system Compression class N Ventilated evaporator Cyclic defrosting Vending system FIFO Delivery door 1 Max weight per drawer 15 kg Evenly distributed 30 kg...

Page 10: ...ct is exceeded SPIRALI FASTER 2T with an electronic system make it possible to have two areas with different temperatures specifically top drawer area where the temperature is stratified from 9 C to 14 C ideal for shelf stable products bottom drawer area where the temperature can be set at 3 C for a good preservation of perishable food substances which would not otherwise resist higher temperature...

Page 11: ...rea where the temperature can be set at 3 C for a good preservation of perishable food substances which would not otherwise resist higher temperatures To comply with HACCP principles Hazard Analysis and Critical Control Points a control called the refrigeration safety device is provided in this area to prohibit the sale of the product if the temperature exceeds the temperature which could cause th...

Page 12: ...problem with the vending machine the number of the current alarm appears on the display 2 Coin return button this push button is used to release any coins jammed in the coin mechanism and return them to the coin return cup 3 Coin slot the customer inserts the credit required to purchase the product in this slot 4 Delivery door is used by the customer to collect the purchased product 5 Coin return ...

Page 13: ...e bottom of the cabinet behind the collection pocket it keeps the internal temperature of the vending machine at the set value 3 Electric panel All the electrical connections the power boards and the fuses are housed in the electric panel which is located in the lower part of the cabinet behind the collection pocket 4 Door micro sends a door open signal to the board 5 Coin box 6 DRAWER DISPLAY BAR...

Page 14: ...event that the vending machine is laid flat place it in an environment with a temperature no less than 18 C and wait at least 2 hours before setting the machine at work As to the storage of the machines it is appropriate that the environment of conservation is very dry with temperatures between 0 to 40 C Cover the machine after having positioned it in a protected environment and anchor it to preve...

Page 15: ...n cords adaptors or multiple jacks The following instructions are valid only to the United Kingdom The wires in the cable are coloured coded as follows GREEN AND YELLOW EARTH BLUE NEUTRAL BROWN LIVE As the colour of the wires in the cable of this equipment may not correspond to the colour marking in the terminals of your socket proceed as follows The GREEN and YELLOW wire must be connected to the ...

Page 16: ...ct installation use or similar caused by the payment system will be only exclusively exlusively charged to those who have carried out the installation of the machine 6 5 PAYMENT SYSTEM CONNECTION The coin mechanism must be connected and disconnected with the machine switched off The connectors required to connect the coin mechanism are located next to the main board The vending machine is set up f...

Page 17: ...t hour 6 For brik products adjust the end 90 in advance NOTE Products in bags or boxes must be correctly placed The sealed edge of the bag can slip under the spiral wire not allowing the fall of the bag It is recommended to fold the edge forward and upward before inserting the bag in the space of the spiral Products like cakes biscuits handle with care objects etc should be placed in the lower dra...

Page 18: ...tween spacer and product 8 3 PRODUCT EXPELLER fig 3 The expeller B can be used when there are products in sacks like chips or others The expeller will help them coming out of the spiral It is hooked up at the end of the spiral and acts as an additional part of the product to vend pushing it out of the drawer 8 4 VENDING A PRODUCT After loading the machine setting the selling prices for each produc...

Page 19: ...ia Lago di Vico 60 SCHIO VI tel 39 0445 502011 fax 39 0445 502010 e mail info fas it E N G L I S H 9 FUNCTION PROGRAMMING KEYBOARD Above the coin mechanism door there are two push buttons having the following functions 1 Programming Button 2 Not used ...

Page 20: ...oftware versions Select the language for the descriptions in the programming menu and machine configuration Enter the submenu to set various machine parameters Cancel blocking and active errors Display and cancel error chronology Enter the sub menu to set the logic interface multimedia files and engine updates View sales data Info Languages Machine parameters Export EVADTS data Sale test Exit Upda...

Page 21: ...e Access to sales test and display current and operative selections 9 1 MACHINE PARAMETERS Exit and return to previous screen Set currency and discount mode Set LED switch off on opening the door and reduce standby brightness Display stroke counter and enable oven column management Configure the photocells Exit General enables Photocells Refrigeration unit Payment systems Timer Drawer display Mana...

Page 22: ... programming sub menu Set the weekly timer Configure the drawer displays Enter the sub menu for selection management prices photocells messages inhibits Import and export machine configuration 9 1 1 GENERAL ENABLES Currency select the desired currency Exit Currency Discount mode Buzzer enable Reduce standby lighting Switch off lighting when door is open Pocket lighting always ON Microwave module m...

Page 23: ...atically through the communication protocol between machine and reader only possible for MDB cashless systems which are provided with this option Buzzer enable tick the box to enable operation of the buzzer during machine operation ZĞĚƵĐĞ ƐƚĂŶĚďLJ ůŝŐŚƚŝŶŐ tick this box to reduce brightness during energy saving slots see Weekly Timer sub menu If this option is disabled the LEDs are completely switc...

Page 24: ...ts on the sensitivity of the reading of the system The lower the value set in this parameter the higher the sensitivity of the system The value can vary from a minimum of 5 to a maximum of 30 Options the selection made in this drop down menu determines how the machine will react if the product is not delivered Possible settings are as follows Select another product Possibility of making another se...

Page 25: ...Select another product or Automatic credit delivery will be triggered depending on whether the single or multi sale parameter has been set Also in this case the function must be enabled for each selection drawer or total see previous point The system then makes it possible to set the empty option which if enabled blocks the selection until the next opening of the main door in the event of failure ...

Page 26: ...3 C This value can be varied between 2 to 25 C Defrost termination temperature every time the compressor pauses the temperature of the evaporator is controlled by the evaporator feeler This command allows the evaporator temperature to be set above which after dripping the compressor can restart operating this is to ensure complete defrosting of the evaporator itself The command is pre set at 3 C a...

Page 27: ...s command is pre set at 60 min but can be varied from 30 to 360 min Refrigerator safety temperature sets the trigger temperature for the safety device that is the temperature above which it prevents the machine from vending the selected product This control is disabled when the machine is switched on and after the door is shut for the period of time set in Refrigerator safety action delay The pre ...

Page 28: ...45 502011 fax 39 0445 502010 e mail info fas it E N G L I S H 9 1 4 PAYMENT SYSTEMS 9 1 4 1 TYPE Payment system Single multi sale Enable change giver engine Coin insertion microswitch Change giver motor cycle interval Exit Exit Type Settings Setting the payment system out of order signal ...

Page 29: ...on or used for a new selection Setting the signal for payment system out of order it is possible to choose whether to block the vending machine if the payment system is out of service Enable change giver engine enables the change giver motor Coin insertion microswitch it is possible to enable the presence the microswitch involved in coin insertion set a change giver motor cycle at time intervals i...

Page 30: ...n The Price display function can be enabled disenabled When enabled the machine will exclusively use the price information indicated by the payment system Level of coins for exact amount a value between 0 and 15 representing the number of coins to be added to the minimum level fixed in the coin return tubes can be programmed in order to quit the exact amount condition Exact amount equation The com...

Page 31: ...credit card reader it is possible to tick the box and enable the credit card function The icon Inhibit coins can be used to block acceptance of particular coins by the coin mechanism The icon Inhibit exact amount coins is used to block acceptance of certain coins when very little change is due i e when the display shows the message Insert exact amount only ...

Page 32: ...ay ticking this box enables the option to maintain overpay at the user s disposal for an indefinite period of time Purchase obligation before change is given when this box is ticked the customer is obliged to complete the purchase before receiving change This is to prevent the coin mechanism being used as a coin changer If the purchase does not happen change will be given Maximum cash credit Maxim...

Page 33: ...lues transmitted by the coin mechanism Inhibit cashless credit display prevent or enable display of credit from the MDB cashless device key or card reader When the box is ticked the credit for the cashless device is not displayed Level of coins for exact amount This command is for setting for each change giving tube the number of coins below which the machine can be considered to be in a condition...

Page 34: ...o 60 SCHIO VI tel 39 0445 502011 fax 39 0445 502010 e mail info fas it E N G L I S H On inserting coins into the tubes the relative bar chart T1 Tube 1 is updated to show the number of coins inserted on top To empty a tube click on the icon of the tube in question ...

Page 35: ...11 fax 39 0445 502010 e mail info fas it E N G L I S H 9 1 5 TIMER The weekly timer settings sub menu has the following options 1 Energy saving 2 Time band discounts 3 Prevent selections Energy saving Time band discounts Disenable selections Exit Exit Enable Day Interval 1 Interval 2 Interval 3 ...

Page 36: ...y from the drop down menu it is then possible to set 3 daily periods when this function is enabled inhibited The second timer manages Time band discounts If this option is enabled the sequence described in the previous paragraph is repeated The third timer manages Disenable Selections If this option is enabled the sequence described in the previous points is repeated The inhibition is then set for...

Page 37: ...on with door open Show product description in stand by mode Drawer Display 1 Drawer Display 2 Drawer Display 3 Drawer Display 4 Drawer Display 5 Drawer Display 6 Drawer Display 7 Backlight Drawer 1 Backlight Drawer 2 Backlight Drawer 3 Backlight Drawer 7 Backlight Drawer 6 Backlight Drawer 5 Backlight Drawer 4 Display mode with promotional messages Display mode without promotional messages Long me...

Page 38: ...on enter the number of the drawer and select the type standard sandwich or custom depending on the mechanical configuration of the drawer itself and press ENTER to save the selection The result will appear immediately on the display bar If the configuration is correct the wording associated with each selection will be centred with regard to the partitions that delimit each selection If you select ...

Page 39: ...ke four possible settings maximum brightness value 100 brightness value 75 brightness value 50 and minimum brightness value 25 Display mode with promotional messages Set the option for displaying promotional messages The latter are text strings displayed on the bar display in correspondence to each product in alternation with the price of the product The text can be entered using the Display Messa...

Page 40: ... to previous screen Read and store machine configuration Not available Used to set the prices of selections Used to insert promotional messages Used to enter a product code stock level and capacity Used to inhibit requested selections Exit Read configuration Prices Display messages Product management Product pushers Photocells Disable selections Cascade Heating times Global configuration ...

Page 41: ...available Used to set the heating times in the presence of a potential Wave Module 9 1 7 1 PRICES Access each selection by clicking on the corresponding spiral from the screen displayed Then set the price line and three different prices Price 1 full price Price 2 discount price based on the discount mode set in the General enables Price 3 price for third price table MDB only After setting the pric...

Page 42: ...each selection by clicking on the corresponding spiral using the screen display After entering the text of the promotional message it can also be applied to the entire drawer or the entire machine by ticking the appropriate box 9 1 7 3 PRODUCT MANAGEMENT Access each selection by clicking on the corresponding spiral using the screen display You can then enter Product code 4 digits ...

Page 43: ...ese values they can also be applied to the entire drawer or the entire machine by ticking the appropriate box 9 1 7 4 DISENABLE SELECTIONS Access each selection by clicking on the corresponding spiral using the screen display After deciding whether to disenable the selection or not these settings can also be applied to the entire drawer or the entire machine by ticking the appropriate box ...

Page 44: ...ection these settings can also be applied to the entire drawer or the whole machine by checking the appropriate box 9 1 7 6 PRODUCT PUSHERS Access each selection by clicking on the corresponding spiral using the screen display After deciding whether or not to enable the product pusher for selection it is possible to indicate the thickness of the product loaded value used if photocells are not enab...

Page 45: ...02011 fax 39 0445 502010 e mail info fas it E N G L I S H 9 1 7 7 HEATING TIMES After enabling the microwave management module in the General Enables icon heating times can be set if a Wave Module is present using the screen depicting these selections Values can be set from 0 to 180 seconds ...

Page 46: ... cloning from another DA using a USB key inserted into one of the sockets on the HUB card highlighted in the photo The file created has the filename DAT extension To import such data simply select the desired file stored on the USB key and it will be copied into the machine If this file is used in VMC Live it must be renamed using only the first 8 digits after the name of the D A for example FASTE...

Page 47: ... mail info fas it E N G L I S H 9 2 CONTROL PANEL Exit and return to previous screen Update interface type Update customizing Exit Close application Update interface type Update customizing Update multimedia Update engine Identification parameters Set clock Tablet settings Settings Copy from USB Fine tune File server ...

Page 48: ...HIO VI tel 39 0445 502011 fax 39 0445 502010 e mail info fas it E N G L I S H Update multimedia Update engine Identification parameters Reset engine Do not use Used to set date and time Allows access to tablet settings Do not use Used to copy files from USB key Do not use ...

Page 49: ...ust be pre loaded on to the tablet using a USB pen drive Remote upgrade is completely automatic the tablet connects to the specific server downloads and installs the file and then runs the interface The interface file is compressed zip its name comprises the prefix M followed by the code identifying the interface e g M00000003 zip To load this file up to the tablet after copying it to a USB pen dr...

Page 50: ...ly in which case the customization file must be pre loaded on to the tablet using a USB pen drive Remote upgrade is completely automatic the tablet connects to the specific server downloads and installs the file and then runs the interface updated with the new customization The interface customization file is compressed zip Its name comprises the prefix letter C followed by the code identifying th...

Page 51: ...y automatic the tablet connects to the specific server downloads and installs the file and then runs the updated interface with the new multimedia content The multimedia content file is compressed zip its name comprises the prefix MULTI followed by the code identifying the interface e g MULTI00000003 zip To load this file up to the tablet after copying it to a USB pen drive proceed as follows Inse...

Page 52: ...play totals regarding the transactions carried out since the initialization of the machine Display totals regarding the transactions carried out but unlike the values displayed with the previous icon they can be reset Displays sales data for each selection Used to reset sales data by entering an access code CODE 1221 Exit Cash flow Resettable cash flow Single selection counter Cancel resettable da...

Page 53: ...9 0445 502010 e mail info fas it E N G L I S H 9 4 EXPORT EVA DTS DATA Used to export EVA DTS data to a USB key N B Use the USB port on the HUB card of choice between the 3 shown in the photo 9 5 UPDATE MAINBOARD Used to update main card software N B Use the USB port in the HUB card shown in the photo ...

Page 54: ...ons will be highlighted in green Touching an individual selection activates the corresponding spiral motor Selections that are out of service will be highlighted in red while those not in their home position having made a quarter turn will displayed orange selections can be reset by rotating them each time the relative number is pressed ATTENTION Rotating the selection to reset it with the door op...

Page 55: ...39 Communication break during sale cycle without credit collection 18 38 39 Communication break during sale cycle with credit collection 30 38 39 Fridge safety has intervened 31 38 39 Photocell test error 32 38 38 39 Photocell calibration error 39 38 39 Photocell safety 51 38 39 Interruption of peripheral connection at the beginning of the sale cycle 55 Payment system out of service 61 Number sele...

Page 56: ...everal dispensing operations in the TEST VEND mode see paragraph FUNCTION PROGRAMMING KEYBOARD 11 2 PROCEDURE FOR REPLACING SPIRALS AND EXPELLER MOTOR GROUP The machine is supplied with drawers with spirals of different diameters and pitches To vary their quantity or their order proceed as follows Switch off the machine by means of the main switch and pull out the power plug Open the main door Pul...

Page 57: ... drawer Push the drawer until it engages in the locked position Insert the electric connector A Close the main door Energise the machine by means of the main switch 11 4 MODIFYING THE DRAWER NUMBER Vending machines with 6 drawers can be transformed into machines with 7 drawers by proceeding as follows Switch off the machine by means of the main switch and pull out the power plug Pull out all the d...

Page 58: ...cation of the temperatures inside the machine it is necessary to use the proper side panel as explained in Chapter 3 To change the side panels in the vending machine remove the drawers as explained previously remove all the guides ref B act on the top part of the perforated side panel by pulling it towards the inside of the machine as in fig 8 It is now possible to extract the side panel and fit t...

Page 59: ...in the number of drawers installed in the automatic vending machine or if their position is rearranged it is advisable to adhere strictly to the recommended measurements set out in the following table for a correct winding of the wiring when the drawer is pulled out TYPE OF DRAWER RUNNER DIMENSION A mm Drawer with standard runner 1 60 Drawer with reinforced runner 2 70 Any drawer with bottle disch...

Page 60: ... 4 Insert the new spiral with small diameter motor unit in the right hand slot and connect it to the wiring on the drawer Add the new divider in between the two spirals det 2 Install the new price and selection labels Insert the modified drawer and make sure that the connector is plugged in Programme the new selections at the desired sale price Test the new selections to ensure that they work corr...

Page 61: ...pocket To remove the refrigeration unit lower the two levers located on the side of the evaporator box ensure that the gasket positioned on the top edge of the evaporator box is not attached to its lodging pull the special handle CAUTION beware of the cables Control panel When the product collection pocket is removed the entire vending machine remains energised Total isolation from the electric po...

Page 62: ... for damage caused by the incorrect use of such detergents or by the use of toxic agents With sanitising products chlorine based detergents or similar products Inside cabinet drawer zone drawers display window Remove detergent disinfectant and foodstuff residues with a damp sponge before restarting the machine At each reload or at least every 5 days With vacuum cleaner or compressed air Remove the...

Page 63: ...FASTER TM T Issue 00 63 FAS INTERNATIONAL S p A Via Lago di Vico 60 SCHIO VI tel 39 0445 502011 fax 39 0445 502010 e mail info fas it E N G L I S H PAGE LEFT INTENTIONALLY BLANK FOR NOTES ...

Page 64: ...64 FASTER TM T Issue 00 FAS INTERNATIONAL S p A Via Lago di Vico 60 SCHIO VI tel 39 0445 502011 fax 39 0445 502010 e mail info fas it E N G L I S H PAGE LEFT INTENTIONALLY BLANK FOR NOTES ...

Reviews: