11
Revision date: 05.13.20 112534
1. Take the reservoir and drill the bulkhead fitting hole using a
2-1/4" hole saw bit
. Review photos and diagrams for position.
ATTENTION:
Use the pump to determine the hole position on the reservoir. Set the pump and reservoir on the same level surface and use the diagram
on the next page to mark the bulkhead location on the reservoir. Adjust as needed to ensure the entire bulkhead fitting is against the flat surface of the
reservoir. Dashed line outlines area for bulkhead fitting.
2. Attach the WF2392 bushing and 111303 screen to the threaded body of the bulkhead fitting. Hand tighten until snug.
3. Attach the bulkhead assembly to the reservoir. Hex nut and thin flat washer are outside the reservoir. Tighten until snug using large adjustable pliers.
4. Continue with the next procedure.
WF2392
Bushing
111303
Screen
Inside reservoir photo
showing fittings.
Install rubber seal
inside reservoir.
3
DRILL RESERVOIR AND INSTALL BULKHEAD AND RELATED FITTINGS
Install hex nut and flat
washer outside reservoir.
WF8582 Bulkhead Fitting
Installed
Assembly Instructions—Reservoir Preparation
WF8582
Sample Reservoir
Step 1
Identify hole position. Use inlet side of pump
to determine the center of the bulkhead fitting.
REMEMBER:
Entire bulkhead must remain
within the flat surface of the reservoir.