![background image](http://html1.mh-extra.com/html/farfisa/project-series/project-series_technical-manual_3558207188.webp)
186
(MT12 - Gb2004)
Si 312T/2
I
NTERCOMS *
VIDEO INTERCOMS *
TELECOMMUNICA
TION
TWO-WAY VIDEO INTERCOM-TELEPHONE INTERCOMMUNICATING SYSTEM WITH PABX CONNECTED TO ONE EXTERNAL
DOOR STATION
Q.ty
Article
Description
4
ST 7100W
Studio series monitor
4
WB7100
Bracket for monitor
8
ST740W
Studio series telephone
8
WB700
Bracket for telephone
1
FT208P
PABX
1
ES60-ES65
Intercom-telephone interface for PABX
1
DV2D
Video distributor
1
1281
Power supply
1
1382
Timer
1
PA **
Door release push-button (optional)
1
SE **
Electric door lock (12VAC-1A)
Door station series Mody
1
MD72
Module frames with back box
1
MD12
Module for electric door speaker
1
MD82
Hood cover
1
MD92*
Rain shelter with module frames
1
MD30
Electric door speaker (amplifier)
1
MD41D
Camera
Door station series Matrix
1
MA42
Camera module with integrated audio amplifier
1
CV01
Video signal converter
1
MA22
Button modules
1
MA62
Front frame
1
MA72
Back box and module frames
* Rain shelter is use instead of back box and hood cover.
** Articles not supplied by ACI Farfisa.
Notes
- If the maximum number of extensions is 5,
you can use the PABX FT105P.
- For the video connection with twisted pair,
use the camera MD41D or add the video
converter CV01 (see page 172).
- For wires dimensioning refer to the installa-
tion instructions and table on page 91.
- For the connection of name plate lamps read
notes 6, 7 and 8 of the installation instructions
on page 91.
- If the control switching ON is necessary, con-
nect terminal 4 of the timer (dashed wire).
Programming
When using the PABX, the following program-
ming must be absolutely carried out:
- intercom interface activation
- activation to receive intercom calls
- how to assign incoming external lines
- how to assign outgoing external lines
See pages 167 and 168.
Application diagram
When using MD200 amplified external door stations, place this diagram on the diagram on page
187 and line it up with the riser.
twisted
pair
WB7100
On bracket WB7100 you must
move jumper J2 from position