32
(MT12 - Gb2004)
Si 11MO/2
I
NTERCOMS
*
V
IDEOINTERCOMS
*
T
ELECOMMUNICA
TION
INTERCOMS WITH PRIVATE CONVERSATION CONNECTED TO 1 EXTERNAL DOOR STATION.
In each intercom it is necessary:
- to cut the jumper (W1) that links
the terminals 3 and 7;
- to move the connection of the
buzzer from terminal 3 to 7;
- to activate the connection between
terminal 7 of the intercom and the
(minus) of the private conversa-
tion module.
In all private conversation modules
cut the resistance R1.
Intercoms Project series
6
2
9
1
3
5
7
2 1 3 6
C
B
SM 50
R1
10K
W1
P
R
O
J
E
C
T
Floor call
This work diagram allows for differ-
entiating the floor-call from the call
from the push-button panel.
Q.ty
Article
Description
...
PT 510 *
Project series intercom with 1 call button
...
SM 50
Private conversation module
1
PRS235
Power supply
1
PA **
Door release push-button (optional)
1
SE **
Electric door lock (12VAC-1A)
Door station series Mody (for items selection refer to pages 12÷15)
1 row
2 row
...
MD71÷74
MD71÷74
Module frames with back box
1
MD10-11-12
MD10-122-124 Modules for electric door speaker
...
MD21 ÷ 24
MD222 ÷ 228
Button modules
...
MD20 - 50
MD20 - 50
Blank and info modules
1
MD82 ÷ 812
MD82 ÷ 812
Hood covers
1
MD92 ÷ 912 (
2
)
MD92 ÷ 912 (
2
)
Rain shelters with module frames
1
MD30
MD30
Electric door speaker (amplifier)
Door station series Matrix (for items selection refer to pages 20 and 21)
...
MA71÷73
Module frames with back box
1
MA10P-11P-12P
Modules with integrated audio amplifier
...
MA20-22-24
Blank and button modules
...
MA61÷63
Front frames
... Refers to number of users.
* Besides the mentioned model all the intercoms from the Project, PuntoVirgola, 900 and 700 can be
installed.
** Articles not supplied by ACI Farfisa.
(
2
) Rain shelters are used instead of back boxes and hood covers.
Working instructions. See page 27.
Notes
- For the connection of name-plate lamps, read notes 6, 7 and 8 of the installation instructions on page 26.
- For wires dimensioning refer to the installation recommendations and table on page 26.
- Telephones can be used instead of intercoms (see “telecommunication” section).
- For other types of push-button panels see pages 22 and 23 or the general catalogue.
Application diagram
When using MD100, MD200, RP100, RP200 and UP amplified external door stations, place this diagram
on the diagram on page 33 and line it up with the riser.
One or two-way systems can be realized with RP and UP series. As regards the Mody series, multi-family
systems can be realized by adding the required quantity of button modules.
Warning.
- For alternate current wires refer to note 6 of the installation instructions on page 26.
Add one buzzer
SR41 to every