Page 1: ...TECHNICAL MANUAL 2004 ALTERNATE CURRENT CALL SYSTEMS...

Page 2: ...and video intercom system must be kept separate from the mains or any other electrical installation as required by International Safety Standards WARNINGS An all pole mains switch with a contact separ...

Page 3: ...coms Internal stations External door stations Power supplies control units and service modules Installation instructions Installation diagrams Telecommunication Internal stations Intercom telephone in...

Page 4: ...traditional intercom and video intercomsystemsinwhichinternalstationsuse telephones with monitors for video intercom telephone functions instead of intercoms or videointercoms Inthiscaseintercomconnec...

Page 5: ...unicatingintercomsconnectedto1externaldoorstationwithsinglecalls Electronicbellforinternalcalls Si111L 5M 5intercommunicatingintercomsconnectedto1externaldoorstationwithcommoncall Electronicbellforint...

Page 6: ...nd PT520W intercoms PT501 Individual push button unit Note We recommend to insert the LED module PT502 and bell silencer module PT515 in the bottom 2 slots marked by and To insert them properly it s n...

Page 7: ...0 electronic bell module SR41 electronic buzzer module 6 W1 2 9 1 3 5 7 9 7 SR40 Electronic bell module see inter communicationdiagrams Terminals power supply call in put 12Vac 0 5A X1 power supply in...

Page 8: ...and knob for adjusting the volume receivingchannel Thismodelispro vided with two push buttons one for connect ing the audio line and the other one for the electric door lock To optimise speech quality...

Page 9: ...804 MD 82 MD 86 MD 808 MD 84 MD 904 MD 93 MD 92 MD 91 Rain shelters with module frames Hood covers Module frames complete with back box PUSH BUTTONS MODY series EXTERNAL DOOR STATIONS MD 94 MD 96 MD...

Page 10: ...R series push button panels for ErreP R door stations by means of 299 1 adapter Terminals 1 audio receiver 2 audio transmitter 3 positive power supply 6 8Vdc 60mA 4 ground Dismountingandprotectionofn...

Page 11: ...positive or alternate voltage input 9 10 connection to optional door lock release Example of composition PUSH BUTTONS MODY series EXTERNAL DOOR STATIONS Installationdiagrams For the installation of t...

Page 12: ...n of cable bush between back boxes The cable bushes must be inserted before brickwork Openings for cables Flushmountingandcablesplacing Mountingofbuttonmodule Lower fixing of the module frame a Lower...

Page 13: ...lignmentofthepanel Hood covers Dismountingoftheframetopsidefromtherain shelter Fixingofthehoodcoverbetweenthebackbox and the module frame Rain shelter Modulesinsertionandwallfixingofrainshelter Mounti...

Page 14: ...call buttons 13 call buttons 1 call button 2 call buttons 3 call buttons 10 call buttons 4 call buttons 5 call buttons 6 call buttons 7 call buttons 8 call buttons 13 call buttons 14 call buttons 11...

Page 15: ...3 2 MD73 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 3 MD73 3 MD73 3 MD73 3 MD73 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 4 MD74 4 MD74 4 MD74 4 MD74 4 MD74 4...

Page 16: ...ns 82 call buttons 62 call buttons 68 call buttons 32 call buttons 22 call buttons 24 call buttons 26 call buttons 2 call buttons 4 call buttons 6 call buttons 20 call buttons 8 call buttons 10 call b...

Page 17: ...2 MD73 2 MD73 2 MD73 2 MD73 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 3 MD73 3 MD73 3 MD73 3 MD73 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 4 MD74 4 MD74 4 M...

Page 18: ...om installations Thepush buttonelementshavebeendeveloped to allow both for horizontal and vertical configuration MA 71 MA 72 MA 73 MA 61 MA 63 MA 62 Front frames Module frames complete with back box P...

Page 19: ...esterminalboards Reception audio line Transmission audio line Power supply input for electric door speaker 6 12Vdc Audioground Alternated power supply input or ground for name plate Led AC or DC power...

Page 20: ...f the push button panel at a height of about 1 65m 5 5 from the floor keeping the front edges flush mounted and vertical to the finished plaster Insertion of spacers between back boxes Spacers and cab...

Page 21: ...the electrical system it is recommended to insert the metal plate supplied with the product in the back box opening asshowninthefigure Theplateisusedtohooktheframe withpre assembledmodules Leavethepl...

Page 22: ...ATIONS I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION 6 call buttons 7 call buttons 10 call buttons 8 call buttons 12 call buttons M A T R I X 46 call buttons 44 call buttons 41 call buttons 40 call bu...

Page 23: ...4 11 MA24 11 MA24 1 MA71 1 MA71 1 MA72 1 MA72 1 MA72 1 MA72 1 MA73 1 MA73 1 MA73 1 MA73 2 MA72 2 MA72 2 MA72 2 MA72 2 MA73 2 MA73 2 MA73 2 MA73 2 MA73 2 MA73 2 MA73 2 MA73 4 MA72 4 MA72 4 MA72 4 MA72...

Page 24: ...ht It can be installed on the wall with expansion plugs or on a wall box RP200 2 button amplified door station Technical data Power supply 13Vac Operating current 130mA Terminals 2 audio receiver 1 au...

Page 25: ...volume adjustment UP 11 Amplified push button panel with 1 call button Fittable in all 4 1 intercom and intercommunicating systems Complete with electric door speaker amplified in the two channels vol...

Page 26: ...Output terminals Ground Audio line power supply 8Vdc 0 1A X Power supply for auxiliary services 12Vdc 0 2A Power supply 13Vac for name plate lamps exchangers continuous load 0 6A electric door lock a...

Page 27: ...vices e g stair lights call for 4 or more bells door release etc ItcanbeinstalledonDINbarorwithtwoscrews In housing DIN bar 3 modules A Technical data Power supply 13Vac 12 24Vdc Current consumption 0...

Page 28: ...nect name plate lamps or other devices powered with alternate current to terminal 4 of the speaker unit 2 wires must originate from terminal minus sign of the power supply one for terminal4ofthespeake...

Page 29: ...ion When the handset is replaced the system returns to the rest condition If a user does not replace the handset properly the next call from another intercom automatically cuts him out of the audio co...

Page 30: ...bsenceofmainvoltage Short circuitorover loadoftheterminalsofthepowersupplyoutput Faultypowersupply The lock does not work Faulty lock The cross section of the cables indicatedinboldtypeisinsufficient...

Page 31: ...erhavethesamefunctions Theitemsmayhavemoreterminalsthantheonesshownintheinstallationdiagrams Theexcessterminalsmustnotbeconnected Theintercommunicatinginstallationdiagramsconnectedto1ormoredoorstation...

Page 32: ...ject PuntoVirgola 900and700canbe installed Articles not supplied by ACI Farfisa 2 Rain shelters are used instead of back boxes and hood covers Working instructions See page 27 Notes For the connection...

Page 33: ...31 MT12 Gb2004 Si 11MO 1 INTERCOMS CONNECTED TO 1 EXTERNAL DOOR STATION I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION P R O J E C T P V 9 0 0...

Page 34: ...2 Rainshelterswithmoduleframes 1 MD30 MD30 Electric door speaker amplifier Door station series Matrix for items selection refer to pages 20 and 21 MA71 73 Module frames with back box 1 MA10P 11P 12P M...

Page 35: ...33 MT12 Gb2004 Si 11MO 2 INTERCOMS WITH PRIVATE CONVERSATION CONNECTED TO 1 EXTERNAL DOOR STATION I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION P R O J E C T...

Page 36: ...onmodules MA61 63 Frontframes Refers to number of users Besides the mentioned model all the intercoms from the Project PuntoVirgola 900 and 700 can be installed Articles not supplied by ACI Farfisa 2...

Page 37: ...35 MT12 Gb2004 Si 12MO 1 INTERCOMS CONNECTED TO 2 AUTOMATICALLY SWITCHED EXTERNAL DOOR STATIONS I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION P R O J E C T P V 9 0 0...

Page 38: ...24 Blankandbuttonmodules MA61 63 Frontframes Refers to number of users Besides the mentioned model all the intercoms from the Project PuntoVirgola 900 and 700 can be installed Articles not supplied b...

Page 39: ...37 MT12 Gb2004 Si 13MO 1 INTERCOMS CONNECTED TO 3 AUTOMATICALLY SWITCHED EXTERNAL DOOR STATIONS I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION P R O J E C T P V 9 0 0...

Page 40: ...fier MA20 22 24 Blankandbuttonmodules MA61 63 Frontframes Refers to number of users X Refers to number of secondary door stations Besides the mentioned model all the intercoms from the Project PuntoVi...

Page 41: ...39 MT12 Gb2004 Si 16MO 1 INTERCOM SYSTEM WITH SECONDARY DOOR STATIONS AND 1 MAIN COMMON STATION multiple entrance I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION P R O J E C T P V 9 0 0...

Page 42: ...Frontframes Refers to number of users X Refers to the number of stairways Besides the mentioned model all the intercoms from the Project PuntoVirgola 900 and 700 can be installed Articles not supplied...

Page 43: ...41 MT12 Gb2004 Si 16MO 2 ONE WAY INTERCOM SYSTEM WITH SECONDARY DOOR STATIONS AND 1 MAIN COMMON STATION multiple entrance I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION P R O J E C T P V 9 0 0...

Page 44: ...umber of stairways Besidesthementionedmodelalltheintercomsfromthe Project PuntoVirgola 900and700canbe installed Articles not supplied by ACI Farfisa 2 Rain shelters are used instead of back boxes and...

Page 45: ...43 MT12 Gb2004 Si 17MO 1 INTERCOM SYSTEM WITH SECONDARY DOOR STATIONS AND 2 MAIN COMMON STATIONS multiple entrance I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION P R O J E C T P V 9 0 0...

Page 46: ...3 to 7 In intercoms CT2 move the buzzer mobile connection from terminal 3 to 2 and connect terminals 2 and 7 together For wires dimensioning refer to the installation recommendations and table on page...

Page 47: ...100L 11 2 INTERCOMMUNICATING INTERCOMS I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION P R O J E C T CT1 CT2 230V 127V 0 PRS220 1 1 2 2 9 9 3 3 6 6 7 7 5 5 PT520 PT524 INTERCOMMUNICATING INTERCOMS 2 to...

Page 48: ...lamps read notes 6 and 7 of the installation instructions on page 26 Forwiresdimensioningrefertotheinstallationrecommen dations and table on page 26 Forothertypesofpush buttonpanelsseepages22and23 or...

Page 49: ...MT12 Gb2004 Si 115L 5S 5 INTERCOMMUNICATING INTERCOMS CONNECTED TO 1 EXTERNAL DOOR STATION WITH SINGLE CALLS ELECTRONIC BELL FOR INTERNAL CALLS I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION P R O J E...

Page 50: ...ns and table on page 26 Forothertypesofpush buttonpanelsseepages22and23 or the general catalogue Application diagram When using MD100 MD200 RP200 UP12 and UP200 amplified external door stations RP and...

Page 51: ...COMMUNICATION PA SE MD71 MD11 MD30 1 2 3 4 CT1 CT2 CT3 CT4 CT5 230V 127V 0 G 2 7 C D A PRS226 PT520 PT501 SR40 PT520 PT501 SR40 PT520 PT501 SR40 PT520 PT501 SR40 PT520 PT501 SR40 2 3 4 1 2 9 3 6 5 7 P...

Page 52: ...les not supplied by ACI Farfisa Working instructions As the basic system described on page 27 with the followingvariations The audio functions and door lock opening are auto matically switched to the...

Page 53: ...T12 Gb2004 Si 125L 5S 5 INTERCOMMUNICATING INTERCOMS CONNECTED TO 2 EXTERNAL DOOR STATIONS WITH SINGLE CALLS ELECTRONIC BELL FOR INTERNAL CALLS I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION P R O J E...

Page 54: ...ons Theaudiofunctionsanddoorlockopeningareautomati callyswitchedtothedoorstationwhichhasmadethecall andremaininthisstateuntilacallfromanotherentrance is received Notes For the connection of name plate...

Page 55: ...MT12 Gb2004 Si 121L 5M 5 INTERCOMMUNICATING INTERCOMS CONNECTED TO 2 EXTERNAL DOOR STATIONS WITH COMMON CALL ELECTRONIC BELL FOR INTERNAL CALLS I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION P R O J E...

Page 56: ...les not supplied by ACI Farfisa Working instructions As the basic system described on page 27 with the followingvariations The audio functions and door lock opening are auto matically switched to the...

Page 57: ...T12 Gb2004 Si 135L 5S 5 INTERCOMMUNICATING INTERCOMS CONNECTED TO 3 EXTERNAL DOOR STATIONS WITH SINGLE CALLS ELECTRONIC BELL FOR INTERNAL CALLS I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION P R O J E...

Page 58: ...ons Theaudiofunctionsanddoorlockopeningareautomati callyswitchedtothedoorstationwhichhasmadethecall andremaininthisstateuntilacallfromanotherentrance is received Notes For the connection of name plate...

Page 59: ...MT12 Gb2004 Si 131L 5M 5 INTERCOMMUNICATING INTERCOMS CONNECTED TO 3 EXTERNAL DOOR STATIONS WITH COMMON CALL ELECTRONIC BELL FOR INTERNAL CALLS I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION P R O J E...

Page 60: ...MA61 Frontframe Main entrance MA71 73 Module frames with back box 1 MA10P 11P 12P Modules with integrated audio amplifier MA20 22 24 Blankandbuttonmodules MA61 63 Frontframes P R O J E C T In every i...

Page 61: ...59 MT12 Gb2004 Si 161L 1 ONE WAY INTERCOMMUNICATING SYSTEM WITH SECONDARY DOOR STATIONS AND 1 MAIN COMMON STATION multiple entrance I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION P R O J E C T...

Page 62: ...h2callbuttons PT501 Singlebuttonunit 1 PRS226E Powersupply switcher Refers to number of users Besides the mentioned model all the intercoms from the Project PuntoVirgola 900 and 700 can be installed A...

Page 63: ...CONNECTED TO 1 EXTERNAL DOOR STATION With intercommunication service in 1 or more apartments and private conversation feature with the external door station and the other apartments I NTERCOMS V IDEOI...

Page 64: ...Si 125L 5S Si 135L 5S to power supply to power supply to power supply P R O J E C T Inallintercomsconnectoneofthe two terminals of the single button unit to terminal 7 In all intercoms connect one of...

Page 65: ...COMMUNICATING INTERCOMS I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION 6 INTERCOMMUNICATING INTERCOMS Application diagrams to power supply to power supply P R O J E C T Ineachintercomtocutthejumper W1...

Page 66: ...ply to power supply In intercoms cut the jumper W1 which connects terminals 3 and 7 andapplytheelectronicbuzzerSR40orSR41 fortheapplicationsee the drawings on the page that illustrates the electrical...

Page 67: ...g services In intercoms cut the jumper W1 which connects terminals 3 and 7 andapplytheelectronicbuzzerSR40orSR41 fortheapplicationsee the drawings on the page that illustrates the electrical diagram t...

Page 68: ...TE CURRENT CALL FROM EXTER NAL STATION AND ELECTRONIC CALL FOR EXTENSIONS To match with diagrams Si 111L 5M Si 121L 5M Si 131L 5M to power supply to power supply to power supply P R O J E C T one way...

Page 69: ...P3 P4 P5 P6 1 2 9 3 6 5 PT520 PT501 SR40 PT520 PT501 SR40 PT520 PT501 SR40 PT520 PT501 SR40 PT520 PT501 SR40 PT520 PT501 SR40 PT520 PT501 SR40 230V 127V 0 1471 PRS210 1 6 5 3 SR40 1 I NTERCOMS V IDEO...

Page 70: ...2 INTERCOMMUNICATING INTERCOMS to riser to riser P R O J E C T one way intercommunicating services in apartment building system 3 INTERCOMMUNICATING INTERCOMS In every intercommunicating intercom ap p...

Page 71: ...ing system to riser In every intercommunicating intercom ap plythesinglebuttongroupbyconnectingone of the two button terminals to terminal 7 of the power supply PRS226E Do not use button no 1 for inte...

Page 72: ...ent building system In every intercommunicating intercom ap plythesinglebuttongroupbyconnectingone of the two button terminals to terminal 7 of the power supply PRS226E Do not use button no 1 for inte...

Page 73: ...ons Si 32MO 2 Video intercom system connected to two external door stations one of which only audio Si 33MO 1 Video intercom system connected to three external door stations Si 33MO 2 Video intercom s...

Page 74: ...z Vertical frequency 50Hz Bandwidth 5MHz Video signal on 75 0 8 1 5Vpp Starting up time 1 sec Operating temperature 0 50 C Max permissible humidity 90 RH Inserting of extra buttons Measures for the in...

Page 75: ...adapter Fastenthevideointercomtothetable adapter X1 X2 2C 1C P1 P2 P3 P4 P5 P6 2 4 8 9 10 11 12 13 14 V 1 1 2 3 J1 W1 75 J1 J1 1 2 3 1 2 3 A B 3 1 Positionfortheintercommuni catingservice Position for...

Page 76: ...of wall bracket WB5600 or WB5660 to the back box 1283 U P Plugging in of videointercom connectors to the terminal boards of wall bracket Wall brackets for the PT5660W videointercoms WB5600 The wall b...

Page 77: ...ommunicating service Inserting of extra buttons 1283 Back boxforvideointercomsPT5660W and PV1260 Place the box on the wall at a height of about 1 5m 4 11 from the floor keeping the front edges flush m...

Page 78: ...and recommended height from the floor U P U P Installation of the wall bracket WB5600 or WB5660 to the wall by means of expansion plugs Wall brackets for the PT5860 and PT5860W videointercoms WB5660...

Page 79: ...1 4 X2 8 2C 9 1C 10 P1 11 P2 12 P3 13 P4 14 P5 V P6 R1 75 1 1 3 J2 WB 5660 Audio privacy or intercommunicating service Inserting of extra buttons Supplementary push buttons installation Taking out of...

Page 80: ...acket WB2100 or WB2160 to the wall and recommended height from the floor Installation of the wall bracket WB2100 or WB2160 to the wall by means of expansion plugs Wall brackets for the PV2160 and PV21...

Page 81: ...easeand6supplementaryservicebut tons that can be added for additional services such as control switch ON intercommunicat ingcalls stairlights doorlockrelease etc The buttons are included in the kit of...

Page 82: ...edfortheintercommunicat ing service position A ByusingthePV1260videointercomwithmulti way systems without the intercommunicating service the audio privacy can be restored by positioning the jumper J1...

Page 83: ...nimumillumination 2Lux 2 5Lux Whitebalance auto Sensor CCD 1 4 B W CCD 1 3 colour Number of pixels 291 000 291 000 Horizontalfrequency 15 625Hz 15 625Hz Verticalfrequency 50Hz 50Hz Lens 3 6mm F5 4mm F...

Page 84: ...27 call buttons 5 0 5 0 32 call buttons 28 call buttons 30 call buttons 34 call buttons 5 0 5 0 16 call buttons 7 call buttons 5 0 5 0 11 call buttons 5 0 12 call buttons 1 call button 2 call buttons...

Page 85: ...8 MD24 8 MD24 8 MD24 9 MD24 10 MD24 8 MD24 11 MD24 11 MD24 11 MD24 11 MD24 11 MD24 11 MD24 11 MD24 14 MD24 1 MD72 1 MD72 1 MD73 1 MD73 1 MD73 1 MD73 2 MD72 2 MD72 2 MD72 2 MD72 2 MD73 2 MD73 2 MD73 2...

Page 86: ...54 call buttons 5 0 5 0 64 call buttons 56 call buttons 60 call buttons 68 call buttons 5 0 5 0 32 call buttons 28 call buttons 14 call buttons 20 call buttons 16 call buttons 18 call buttons 5 0 5 0...

Page 87: ...MD228 4 MD228 4 MD228 5 MD228 5 MD228 5 MD228 5 MD228 5 MD228 5 MD228 6 MD228 5 MD228 7 MD228 7 MD228 7 MD228 6 MD228 6 MD228 8 MD228 8 MD228 8 MD228 8 MD228 8 MD228 8 MD228 8 MD228 8 MD228 9 MD228 10...

Page 88: ...he2audiochannelsopportunelyvaryingthe externalknobs Video modules with integrated audio amplifier MATRIX series push button panels EXTERNAL DOOR STATIONS Adjustments Youcanmanuallychangethecameraframi...

Page 89: ...and cables placing For easier connec tion to the electrical system it is recom mendedtoinsertthe metalplatesupplied with the product in the back box open ing as shown in the figure The plate is used...

Page 90: ...ons 5 call buttons EXTERNAL DOOR STATIONS 5 call buttons 7 call buttons 9 call buttons 6 call buttons 11 call buttons M A T R I X 45 call buttons 43 call buttons 40 call buttons 39 call buttons 37 cal...

Page 91: ...MA24 10 MA24 11 MA24 11 MA24 1 MA71 1 MA72 1 MA72 1 MA72 1 MA72 1 MA73 1 MA73 1 MA73 1 MA73 2 MA72 2 MA72 2 MA72 2 MA72 2 MA73 2 MA73 2 MA73 2 MA73 2 MA73 2 MA73 2 MA73 2 MA73 4 MA72 4 MA72 4 MA72 4...

Page 92: ...voltage output for the common of push button13Vac 0 5A intermittentservice H Timed positive voltage output for the camera unit 18 28Vdc 0 5A max F Ground 1 Transmitteraudiochannelinput4 5Vdc 10mA 2 Re...

Page 93: ...h the required cross section for example multi pair telephone cables Only use a single wire with suitable cross section When using multi core cables you must select them with low parasite parameters l...

Page 94: ...create overloads on the video power supply The outputs that are not used must be closed with resistances of 75 that are pro videdinkit Maximum12videodistributorscan beconnectedtogether DV2 DV4 VIDEO...

Page 95: ...Itisnotnecessarytoterminatethe unusedoutputsonthe75 resist ance If more than one video distributor is to be used an extra power supply art 1281 is necessary Connection of art 476 as video amplifier f...

Page 96: ...n diagram Problem reason and solutions Videointercoms shut OFF Ringing tone not present Control switching ON not function ing Absence of main voltage Short circuits or over loading of the output termi...

Page 97: ...ns Theitemsmayhavemoreterminalsthantheonesshownintheinstallationdiagrams Theexcessterminalsmustnotbeconnected The installation diagrams with 1 or more external door stations contained in this technica...

Page 98: ...dule frames 1 MA61 Frontframe 1 MA43 Camera module with integrated audio and call button The rain shelter is used in the place of the back box and hood cover Articles not supplied by ACI Farfisa Worki...

Page 99: ...0 Si 311O 14 One way video intercom system with long distance between video intercom and main power supply Thefollowingarticlesmustbeaddedtotheliston page 96 1 RL37 Relaymodule 1 1281 Powersupply 1 47...

Page 100: ...Electric door speaker amplifier Matrix series for the composition see pages 88 89 UR 1 MA42 43 Camera modules with integrated audio amplifier PB MA20 22 24 Blankandbuttonmodules MA61 62 63 Frontframe...

Page 101: ...99 MT12 Gb2004 I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION coax VIDEO INTERCOM SYSTEM CONNECTED TO ONE EXTERNAL DOOR STATION Si 31MO 1...

Page 102: ...owing variations from the intercom the user has about 40 sec ondstoanswerbyliftingthehandsetandthere fore can speak for an unlimited time with video privacytowardstheotherusers Byreplacingthe handsett...

Page 103: ...004 I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION coax Si 31MC 1 MIXED INTERCOM AND VIDEO INTERCOM SYSTEM CONNECTED TO ONE EXTERNAL DOOR STATION Intercomwithoutprivate conversation Intercomwithprivate...

Page 104: ...nshelters PE 1 MD30 MD30 Electric door speaker amplifier Matrix series for the composition see pages 88 89 PB MA20 22 24 Blankandbuttonmodules MA61 62 63 Frontframes MA71 72 73 Back boxes and module f...

Page 105: ...103 MT12 Gb2004 I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION coax VIDEO INTERCOM SYSTEM CONNECTED TO ONE EXTERNAL DOOR STATION WITH SURVEILLANCE CAMERA Si 31MO 2...

Page 106: ...itchONforthe2video entrancesitisnecessarytomakethedashed lineconnectionsanduseWB5160 WB5660 WB2160 WB1260 wall brackets The wall bracketsareconfiguratedtoworkwithoutthe audio privacy to restore it the...

Page 107: ...105 MT12 Gb2004 I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION coax VIDEO INTERCOM SYSTEM CONNECTED TO TWO EXTERNAL DOOR STATIONS Si 32MO 1...

Page 108: ...e of the back box and hood cover Articles not supplied by ACI Farfisa Notes IfthecontrolswitchingONisnecessary con nect terminal 4 of the timer dashed wire Fortheconnectionofnameplatelampsread notes6...

Page 109: ...107 MT12 Gb2004 I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION coax VIDEO INTERCOM SYSTEM CONNECTED TO TWO EXTERNAL DOOR STATIONS ONE OF WHICH ONLY AUDIO Si 32MO 2...

Page 110: ...Refers to number of users The rain shelter is used in the place of the back box and hood cover Articles not supplied by ACI Farfisa Notes TohavethecontrolswitchONforthe3video entrancesitisnecessarytom...

Page 111: ...109 MT12 Gb2004 I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION coax VIDEO INTERCOM SYSTEM CONNECTED TO THREE EXTERNAL DOOR STATIONS Si 33MO 1...

Page 112: ...3MO 2 Refers to number of users Therainshelterisusedintheplaceoftheback box and hood cover Articles not supplied by ACI Farfisa Notes To have the control switch ON for the 2 video entrances it is nece...

Page 113: ...111 MT12 Gb2004 I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION coax VIDEO INTERCOM SYSTEM CONNECTED TO THREE EXTERNAL DOOR STATIONS ONE OF WHICH ONLY AUDIO Si 33MO 2...

Page 114: ...ankandbuttonmodules MA61 62 63 Frontframes MA71 72 73 Back boxes and module frames Si 33MO 7 Refers to number of users The rain shelter is used in the place of the back box and hood cover Articles not...

Page 115: ...113 MT12 Gb2004 I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION coax VIDEO INTERCOM SYSTEM CONNECTED TO THREE EXTERNAL DOOR STATIONS TWO OF WHICH ONLY AUDIO Si 33MO 7...

Page 116: ...rfisa Notes Connect the video intercom terminal 4 wire shownwithdottedline ifthecontrolswitchon from the secondary door station is required Fortheconnectionofnameplatelampsread notes6 7and8oftheinstal...

Page 117: ...IN COMMON VIDEO STATION multiple entrance Si 36MO 2 Application of Matrix push button panel The button common terminal of every module CANNOT be separated Forthecompositionofthe push button panel at t...

Page 118: ...of users X Refers to number of secondary door stations The rain shelter is used in the place of the back box and hood cover Articles not supplied by ACI Farfisa Si 36MO 3 Connection of two door locks...

Page 119: ...1 MAIN COMMON VIDEO STATION multiple entrance Si 36MO 3 Application of Matrix push button panel The button common terminal of every module CANNOT be separated Forthecompositionofthe push button panel...

Page 120: ...al 4 wire shownwithdottedline ifthecontrolswitchon from the secondary door station is required Fortheconnectionofnameplatelampsread notes6 7and8oftheinstallationinstructions on page 91 For wires dimen...

Page 121: ...MONSTATIONONLYAUDIO multipleentrance Si 36MO 4 Application of Matrix push button panel The button common terminal of every module CANNOT be separated Forthecompositionofthe push button panel at the ma...

Page 122: ...n shelter is used in the place of the back box and hood cover Articles not supplied by ACI Farfisa Si 36MO 5 Connection of two door locks of which the secondary is always activable in a system with mu...

Page 123: ...COMMUNICATION coax VIDEO INTERCOM SYSTEM WITH ONE WAY SECONDARY DOOR STATIONS ONLY AUDIO AND 1 MAIN COMMON VIDEO STATION multipleentrance Si 36MO 5 Application of Matrix push button panel Connect all...

Page 124: ...t the video intercom terminal 4 wire shownwithdottedline ifthecontrolswitchon from the secondary door station is required Fortheconnectionofnameplatelampsread notes6 7and8oftheinstallationinstructions...

Page 125: ...123 MT12 Gb2004 I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION coax VIDEO INTERCOM SYSTEM WITH SECONDARY VIDEO STATIONS AND 2 MAIN COMMON VIDEO STATIONS multiple entrance Si 37MO 1...

Page 126: ...nections shown with dotted lines b apply the module 1443E inside the timer 1382 see page 90 c useexpandablebracketsWB5160 WB5660 WB1260 WB2160 verifyingthatthe mobile jumper J1 located on the video in...

Page 127: ...onal diagrams Extension in one apartment of a MULTI WAY system To realise a multi way system with several video intercoms and or intercoms in parallel in one apartment with or without intercommunicati...

Page 128: ...Read notes 1abc 2 and 4 of page 124 Read notes 1abc 3 and 4 of page 124 Read notes 1abc 2 and 4 of page 124 Read notes 1abc 2 3 and 4 of page 124 X1 to be connected to terminal A of art 1382 to termin...

Page 129: ...NG SERVICE Read notes 1abc 2 3 and 4 of page 124 Read notes 1abc 2 3 and 4 of page 124 Read notes 1abc 2 3 and 4 of page 124 Read notes 1abc 2 and 4 of page 124 to terminal I of 1382 to terminal I of...

Page 130: ...VIDEO INTERCOMS VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 or if intercommunicating PT5160 WB5160 PT5660 WB5660 1283 PT5860 WB5660 PV2160 WB2160 PV1260 WB1260...

Page 131: ...ms VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 CT PT510 PV100 924 or if intercommunicating PT520 SR40 PT501 or if intercommunicating PT5160 WB5160 PT5660 WB5660...

Page 132: ...NICATING SERVICE VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 CT PT510 PV100 924 or if intercommunicating PT520 SR40 PT501 or if intercommunicating PT5160 WB5160...

Page 133: ...VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 CT PT510 PV100 924 or if intercommunicating PT520 SR40 PT501 or if intercommunicating PT5160 WB5160 PT5660 WB5660 12...

Page 134: ...CE VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 CT PT510 PV100 924 or if intercommunicating PT520 SR40 PT501 or if intercommunicating PT5160 WB5160 PT5660 WB5660...

Page 135: ...grams to terminal I of 1382 VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 CT PT510 PV100 924 or if intercommunicating PT520 SR40 PT501 or if intercommunicating PT5...

Page 136: ...C PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 CT PT510 PV100 924 or if intercommunicating PT520 SR40 PT501 or if intercommunicating PT5160 WB5160 PT5660 WB5660 1283...

Page 137: ...VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 CT PT510 PV100 924 or if intercommunicating PT520 SR40 PT501 or if intercommunicating PT5160 WB5160 PT5660 WB5660 128...

Page 138: ...VICE to terminal I of 1382 VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 CT PT510 PV100 924 or if intercommunicating PT520 SR40 PT501 or if intercommunicating PT51...

Page 139: ...G SERVICE Read notes 1ac 2 4 and 5 of page 124 Read notes 1ac 3 4 and 5 of page 124 Read notes 1ac 2 4 and 5 of page 124 Read notes 1ac 2 3 4 and 5 of page 124 D 100V 1A diode type 1N4007 D 100V 1A di...

Page 140: ...diode type 1N4007 D 100V 1A diode type 1N4007 VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 or if intercommunicating PT5160 WB5160 PT5660 WB5660 1283 PT5860 WB5660...

Page 141: ...007 D 100V 1A diode type 1N4007 VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 CT PT510 PV100 924 or if intercommunicating PT520 SR40 PT501 or if intercommunicating...

Page 142: ...diode type 1N4007 D 100V 1A diode type 1N4007 VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 CT PT510 PV100 924 or if intercommunicating PT520 SR40 PT501 or if int...

Page 143: ...4007 D 100V 1A diode type 1N4007 VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 CT PT510 PV100 924 or if intercommunicating PT520 SR40 PT501 or if intercommunicatin...

Page 144: ...and 5 of page 124 D 100V 1A diode type 1N4007 VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 CT PT510 PV100 924 or if intercommunicating PT520 SR40 PT501 or if int...

Page 145: ...07 D 100V 1A diode type 1N4007 VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 CT PT510 PV100 924 or if intercommunicating PT520 SR40 PT501 or if intercommunicating...

Page 146: ...124 D 100V 1A diode type 1N4007 VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 CT PT510 PV100 924 or if intercommunicating PT520 SR40 PT501 or if intercommunicatin...

Page 147: ...A diode type 1N4007 D 100V 1A diode type 1N4007 VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 CT PT510 PV100 924 or if intercommunicating PT520 SR40 PT501 or if in...

Page 148: ...D 100V 1A diode type 1N4007 VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 CT PT510 PV100 924 or if intercommunicating PT520 SR40 PT501 or if intercommunicating PT...

Page 149: ...07 D 100V 1A diode type 1N4007 VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 CT PT510 PV100 924 or if intercommunicating PT520 SR40 PT501 or if intercommunicating...

Page 150: ...WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 VC PT5160 WB5100 PT5660 WB5600 1283 PT5860 WB5600 PV2160 WB2100 PV1260 WB1200 1283 CT PT510 PV100 924 or if intercommunicating...

Page 151: ...l door station with twistedpair Si 311T 7 One way video intercom telephone system with PABX and connection to one external door station with twisted pair Si 31MT 1 Mixed video intercom video intercom...

Page 152: ...air lights acti vation or other services Button for communication with external door station Memory buttons Keypad Key R or FLASH Programming key Repeat key Ringing volume adjustment Description WB 70...

Page 153: ...FT105P or FT208P or L and L of the telephone inter face FT11D Table version Apply the 4 anti slip rubber pads in their housings under the table adapter base Make the hole for the telephone cable Block...

Page 154: ...way installations with differentiated door locks activation of relays 3 and 4 etc See the PABX instructions on pages 168 and 169 Tochangeprogramming pick upthehandset press no tone is heard on the lo...

Page 155: ...et Replacethehandsetafterconversation Make a call Pick upthehandset Dialthenumber Replacethehandsetafterconversation Note If the telephone is connected to a Farfisa PABX s you must dial 0 81 or 82 to...

Page 156: ...ideo distributor and camera The number of wires andpossibleinstallationsdoesnotchange Do not forget to position jumper J2 correctly and use the proper input terminals of bracket WB7100 A Video connect...

Page 157: ...1 10 3 2 1 aaaaaaaaaaaaaa aaaaaaaaaaaaaa 4 13 JP1 J2 H 1 2 3 9V 9R 9M 5 F 4 Y X P P 8 1 C C V M V R9 J1 JP2 1 2 3 1 14 U1 1 10 3 2 1 1 Fix the bracket WB7100 to the wall with the 3 fixing points at a...

Page 158: ...P2 1 2 3 1 14 U1 1 10 3 2 1 U P U P 3 Fix the bracket WB7100 with the 2 screwssupplied 4 Maketheconnectiontothebracket terminal board according to the in stallationdiagram 2 Passtheconnectioncablethro...

Page 159: ...with video intercom telephone func tions Wall version 4 Pass the telephone cable through the space between the telephone and the bracket Pull the cable in such a way that the extra part of the cable f...

Page 160: ...iagram 5 Hook the telephone to the bracket WB700 I NTERCOMS VIDEO INTERCOMS TELECOMMUNICATION INTERNAL STATIONS S T U D I O JP1 J2 H 1 2 3 9V 9R 9M 5 F 4 Y X P P 8 1 C C V M V R9 J1 JP2 1 2 3 1 14 U1...

Page 161: ...terminal combination on the junctionbox 1 Apply the 8 anti slip rubber pads in their housings under the base of the table adapters TA7100 and TA700 2 Passtheconnectioncablethroughthe hole in the back...

Page 162: ...for monitor 2 TA700 table adapter for telephone and video memory Toinstallavideomemorymodulenexttothemonitorandtelephone you must insert the 2 plastic templates contained in the packing on the proper...

Page 163: ...5 Screw the brackets WB7100 and WB700 on the table adapters 4 Screw the 4 metallic frames on the table adapters and hook the 2 plastic frames to them see drawing 4 on page 159 6 Hook the monitor and...

Page 164: ...A 7 normally closed contact of relay INSTALLATION The intercom telephone interface FT11D in DIN housing 8 modules A can be installed in suitable electrical box provided with bar sup port in compliance...

Page 165: ...Protection for 1 telephone line PR2 Protection for 2 telephone lines PRAL Protection for electrical line 230Vac WARNINGS Do not install the protections in humid places or near heat sources Do not int...

Page 166: ...answering machines 45 48 Microprocessor control with recorded program Solid stateswitchingmatrix 2 wireinternaltelephonenetwork The other extension lines can also be used but in this case the use of t...

Page 167: ...educe crosstalkproblems check that the ON OFF switch is OFF connectthewiresoftheexternallines1and2toterminalsURB1and URB2 URB1 for FT105P connect the wires of the telephones to DER41 DER48 DER41 DER45...

Page 168: ...43 DER44 DER47 DER42 DER41 J204 IL COPERCHIO CAUTION TO PREVENT THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER RISCHIO DI SCOSSE ELET ATTENZIONE PER EVITARE TRICHE NON RIMUOVERE DANGER 4 2 3 1 CALLER...

Page 169: ...er s needs and for setting the operating mode for the each indi vidual telephone connected to the PABX PROGRAMMING CAN ONLY BE CARRIED OUT FROM EXTEN SION 41 WhenswitchingitON thePABXisprogrammedforst...

Page 170: ...is day 333310 night 333312 0 theextension isnotenabledtohaveconversationswiththeexter nalintercomstation isnotenabledtoactivaterelays door opener stair case lighting etc 1 theextension is enabled to...

Page 171: ...e call control tone wait for the D I S A post dialling tone dial 7 dial the password programmed for the specific external line dial the number of the relay to be activated 1 relay 1 2 relay 2 3 relay...

Page 172: ...lamonitorST7100orST7100Cto your domestic telephone In this case in addi tion to the intercom characteristics described in the previous section you can visualise your ownentrance APPLICATION IN VIDEO I...

Page 173: ...DV2D or DV4D TerminalsXandYofthelastdistributormustbeterminatedwiththe75 resistances supplied with the article It is not necessary to terminate the unusedoutputs Example of connection on 8 risers X Y...

Page 174: ...back of the housing of the camera with the screw supplied a Make the connections as shown on the diagram Check that the jumper J1 is in position 2 3 power supply 21Vdc SYSTEMS WITH CCTV CAMERAS Insta...

Page 175: ...om calls See page 168 If the PABX is only used for the intercom municatingservice withoutconnectiontothe public telephone lines URB1 and URB2 it is necessarytodeactivatetheincomingandout goingexternal...

Page 176: ...ns See pages 27 162 and 168 Notes Ifthemaximumnumberofextensionsis5 youcanusethePABX FT105P Fortheconnectionofname platelamps readnotes6 7and8of the installation instructions on page 26 For wires dime...

Page 177: ...175 MT12 Gb2004 Si 11MT 1 MIXED INTERCOM TELEPHONE SYSTEM CONNECTED TO ONE EXTERNAL DOOR STATION I NTERCOMS VIDEO INTERCOMS TELECOMMUNICATION Trunk lines Trunk line...

Page 178: ...on pages 91 93 Note For wires dimensioning and video connection refertotheinstallationinstructionsandtableon pages 91 93 and read note 3 on page 124 Programming For this type of system the following...

Page 179: ...7 and R10 of the fixing brackets WB7100 add 2 75 resistances between terminals X F and Y F of the last monitor Forthevideoconnectionwithtwistedpair use the camera MD41D or add the video converter CV01...

Page 180: ...udio amplifier MA20 22 24 Blankandbuttonmodules MA61 62 63 Frontframes MA71 72 73 Back boxes and module frames coax Refers to number of users Rain shelters are used instead of back boxes and hood cove...

Page 181: ...179 MT12 Gb2004 Si 31MT 1 MIXED VIDEO INTERCOM VIDEO INTERCOM TELEPHONE SYSTEM CONNECTED TO ONE EXTERNAL DOOR STATION I NTERCOMS VIDEO INTERCOMS TELECOMMUNICATION coax Trunklines Trunkline...

Page 182: ...vers Articles not supplied by ACI Farfisa Working instructions See pages 94 162 and 168 twisted pair WB7100 OnbracketWB7100youmust movejumperJ2fromposition 1 2 to 2 3 Notes If the maximum number of ex...

Page 183: ...181 MT12 Gb2004 Si 31MT 2 VIDEO INTERCOM TELEPHONE SYSTEM CONNECTED TO ONE EXTERNAL DOOR STATION I NTERCOMS VIDEO INTERCOMS TELECOMMUNICATION twisted pair Trunklines Trunkline...

Page 184: ...s to number of users Rain shelters are used instead of back boxes and hood covers Articles not supplied by ACI Farfisa Working instructions See pages 94 162 and 168 Notes If the maximum number of exte...

Page 185: ...183 MT12 Gb2004 Si 32MT 1 VIDEO INTERCOM TELEPHONE SYSTEM CONNECTED TO TWO EXTERNAL DOOR STATIONS I NTERCOMS VIDEO INTERCOMS TELECOMMUNICATION twisted pair Trunklines Trunkline...

Page 186: ...ier 1 MA22 Buttonmodules 1 MA62 Frontframe 1 MA72 Back box and module frames Rain shelter is use instead of back box and hood cover Articles not supplied by ACI Farfisa Notes If the maximum number of...

Page 187: ...5 MT12 Gb2004 Si 312T 1 TWO WAY VIDEO INTERCOM TELEPHONE INTERCOMMUNICATING SYSTEM WITH PABX CONNECTED TO ONE EXTERNAL DOOR STATION I NTERCOMS VIDEO INTERCOMS TELECOMMUNICATION coax Trunkline Trunklin...

Page 188: ...odules 1 MA62 Frontframe 1 MA72 Back box and module frames Rain shelter is use instead of back box and hood cover Articles not supplied by ACI Farfisa Notes If the maximum number of extensions is 5 yo...

Page 189: ...12 Gb2004 Si 312T 2 TWO WAY VIDEO INTERCOM TELEPHONE INTERCOMMUNICATING SYSTEM WITH PABX CONNECTED TO ONE EXTERNAL DOOR STATION I NTERCOMS VIDEO INTERCOMS TELECOMMUNICATION Trunkline Trunkline twisted...

Page 190: ...connected in serial mode inputandoutputfromthevideointercom youmustcutthe75 resistanceR8ofthebracketWB7100andleaveitonlyonthelastvideo intercom Note If the video system is realized with coaxial cable...

Page 191: ...S coax Note If the video system is realized with coaxial cable connected in serial mode inputandoutputfromthevideointercom youmustcutthe75 resistanceR8ofthebracketWB7100andleaveitonlyonthelastvideo in...

Page 192: ...MMUNICATING TELEPHONES Note On bracket WB7100 you must move jumper J2 from position 1 2 to 2 3 twisted pair Note the extension diagrams of these 2 pages can be only applied to Si311T 4 Si31MT 2 and Si...

Page 193: ...TELEPHONE SETS AND 2 INTERCOMMUNICATING TELEPHONES 1 PABX 5 VIDEO INTERCOM TELEPHONE SETS AND 3 INTERCOMMUNICATING TELEPHONES twisted pair to the riser to the riser Trunklines Trunklines Note On brack...

Page 194: ...ow MD226 Button module with 6 push buttons 2 row MD228 Button module with 8 push buttons 2 row PR1 Protection for 1 telephone line PR2 Protection for 2 telephone lines PRAL Protection for electrical l...

Page 195: ...agrams contained in this manual at any time without prior notice The diagrams and information contained in this manual have been carefully verified and are to be considered as reliable However ACI FAR...