ENGLISH
GB-37
Failure code
Problem
Solution
E6
High temperature of
IGBT (2#)
Touch “ON/OFF”
button to restart unit.
Check whether the fan
runs smoothly;
if not , replace the fan.
No Auto-Recovery
F3/F6
Ceramic plate
temperature sensor
failure- -short circuit.
(F3 for 1#,F6 for2#)
Check the connection
or replace the ceramic
plate temperature
sensor.
F4/F7
Ceramic plate
temperature sensor
failure--open circuit.
(F4 for 1#,F7 for2#)
F5/F8
Ceramic plate
temperature sensor
failure—invalid . (F5
for 1#,F8 for2#)
F9/FA
Temperature sensor
of the IGBT failure.
(short circuit/open
circuit for 1#)
Replace the power
board.
FC /FD
Temperature sensor
of the IGBT failure.
(short circuit/open
circuit for 2#)
Summary of Contents for TI60 INF 444
Page 1: ...TI60 INF 444...
Page 2: ......
Page 58: ......
Page 109: ......