8
SPECIFICATIONS
Nominal performance data - R404A
50 Hz
To: Evaporating temperature at dew point (saturated suction temperature)
Tc: Condensing temperature at dew point (saturated discharge temperature)
SC: Subcooling,
SH: Superheat
3 phase - 400 V
60 Hz
To: Evaporating temperature at dew point (saturated suction temperature)
Tc: Condensing temperature at dew point (saturated discharge temperature)
SC: Subcooling,
SH: Superheat
3 phase - 460 V
Compressor model
To = -10°C, Tc = 45°C, RGT= 20°C, SC = 0 K
To = -10°C, Tc = 45 °C , SH = 10 K, SC = 0 K
To = 5°C, Tc = 50°C , RGT = 20°C, SC = 0 K
Cooling
capacity
W
Power
input
W
Current
input
A
COP
W/W
Cooling
capacity
W
Power
input
W
Current
input
A
COP
W/W
Cooling
capacity
W
Power
input
W
Current
input
A
COP
W/W
MPZ038
2995
1419
2.9
2.11
2795
1419
2.86
2.0
5049
1837
3.4
2.75
MPZ048
4005
1896
3.5
2.11
3738
1896
3.49
2.0
6446
2515
4.4
2.56
MPZ054
4464
2154
3.9
2.07
4167
2154
3.86
1.9
7329
2906
5.0
2.52
MPZ061
5030
2522
4.9
1.99
4695
2522
4.86
1.9
8080
3357
6.2
2.41
MPZ068
5707
2905
5.5
1.96
5327
2905
5.48
1.8
9027
3928
7.1
2.30
Compressor model
To = -10°C, Tc = 45°C, RGT= 20°C, SC = 0 K
To = -10°C, Tc = 45 °C , SH = 10 K, SC = 0 K
To = 5°C, Tc = 50°C , RGT = 20°C, SC = 0 K
Cooling
capacity
W
Power
input
W
Current
input
A
COP
W/W
Cooling
capacity
W
Power
input
W
Current
input
A
COP
W/W
Cooling
capacity
W
Power
input
W
Current
input
A
COP
W/W
MPZ038
3545
1657
2.7
2.14
3309
1657
2.71
2.0
5925
2175
3.3
2.72
MPZ048
4680
2271
3.4
2.06
4368
2271
3.43
1.9
7554
2975
4.3
2.54
MPZ054
5306
2576
3.8
2.06
4952
2576
3.81
1.9
8593
3523
5.0
2.44
MPZ061
5912
2978
4.7
1.99
5518
2978
4.71
1.9
9581
3975
5.9
2.41
MPZ068
6765
3410
5.2
1.98
6314
3410
5.21
1.9
10773
4668
6.9
2.31