![Falcon Professional+ FXP 90 Dual Fuel User Manual Download Page 45](http://html.mh-extra.com/html/falcon/professional-fxp-90-dual-fuel/professional-fxp-90-dual-fuel_user-manual_539793045.webp)
41
11. Technical Data
This cooker is designed for use on Natural gas, although a conversion for LP (LPG X Propane (2.54 kPa)) gas is packed with the
cooker.
INSTALLER:
Please leave these instructions with the user.
DATA BADGE LOCATION:
Inside base drawer of cavity and on rear of the appliance.
COUNTRY OF DESTINATION:
Australia.
Connection & Test Pressures
Gas
(Rp½ at right rear)
Electric
Natural Gas
1 kPa
230 V 50 Hz
Propane
2.54 kPa
See appliance data badge for test pressures.
Dimensions
Overall height
minimum 905 mm
maximum 925 mm
Overall width
900 mm;
Overall depth
600 mm
(to fascia)
; 650 mm
(over handles)
Minimum space above hotplate
650 mm
See
‘Positioning of Cooker’
.
Ratings
Oven
Full
Divided
Fan element
3.31 kW
1.65 kW
Top element
3.49 kW
1.75 kW
Browning element
2.11 kW
1.06 kW
Bottom element
1.38 kW
0.69 kW
Hotplate
Bypass
Screw*
Natural Gas 1 kPa
Propane X 2.54 kPa
Input
Injector
Input
Injector
Marking
Size Ø
Marking
Size Ø
Wok burner
55
15.2 Mjh
-1
Internal 88
0.88 mm
15.0 Mjh
-1
Internal 57
0.57 mm
External 168
1.68 mm
External 98
0.98 mm
Large burner
41
12.3 Mjh
-1
165
1.65 mm
12.0 Mjh
-1
89
0.96 mm
Medium burners
33
6.2 Mjh
-1
115
1.15 mm
6.2 Mjh
-1
67
0.68 mm
Small burner
25
3.7 Mjh
-1
92
0.92 mm
3.3 Mjh
-1
48
0.50 mm
* The valves in this cooker are fitted with adjustable bypass screws. The cooker is supplied with the bypass screws set for
Natural gas. For LPG conversion the bypass screws must be screwed all the way down.
Maximum total electric load 230 V
(approximate including oven fans, lights, etc.)
:
3.6 kW.
Summary of Contents for Professional+ FXP 90 Dual Fuel
Page 1: ...Professional FXP 90 Dual Fuel Australia USER GUIDE INSTALLATION INSTRUCTIONS ...
Page 2: ......
Page 4: ...iv ...
Page 46: ...42 ...
Page 47: ...43 ...