![Falcon Professional+ FXP 90 Dual Fuel User Manual Download Page 39](http://html.mh-extra.com/html/falcon/professional-fxp-90-dual-fuel/professional-fxp-90-dual-fuel_user-manual_539793039.webp)
WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
35
Catalytic filter cover
Bracket
Phial retaining
clamp
Protection & primary phials
Pyrolytic phial
4 Ovens
4.1 To Change an Oven Thermostat
DISCONNECT FROM THE ELECTRICITY SUPPLY.
Situated at the back of the oven, behind the right-
hand upper elements, are the primary and protection
thermostats phials. One the right-hand side of the same
element is the pyrolytic phial
(Fig.9-5)
.
To Change the Primary Thermostat
Remove the control panel (see 1.1) and hotplate (see 2.1).
Remove the oven shelves, shelf supports and divider.
Undo the cooker rear cover screws and remove the
covers.
Undo the screw holding the phial retaining clamp to the
bracket. Undo the 2 screws securing the catalytic filter
cover
(Fig.9-6)
.
Track the route of the thermostat capillary from the
rear of the control on the fascia to where it disappears
into the oven. By moving the capillary it will become
obvious which of the 2 phials in the oven it is connected
to. The phial can then be removed.
Feed the thermostat capillary out and clear of the oven,
noting the routing.
Remove the 2 screws fixing the thermostat to the inner
control panel and disconnect the wiring from the
thermostat.
Fit the replacement in reverse order.
To Change the Protection Thermostat
Follow the same procedure as above except that the
control is situated on the rear cover.
Fit the replacement in reverse order.
To Change the Pyrolytic Thermostat
Remove the control panel (see 1.1) and hotplate (see 2.1).
Remove the oven shelves, shelf supports and divider.
Undo the cooker rear cover screws and remove the
covers.
Remove the 2 screws holding the small retaining plate
on the back of the cooker and remove the plate.
Remove the pyrolytic phial.
Fit the replacement in reverse order.
4.2 To Replace the Oven Multi-function Switch
DISCONNECT FROM THE ELECTRICITY SUPPLY.
Move the cooker away from the wall to allow access to
the rear.
Remove the pan supports and burner heads. Remove
the control panel (see 1.1) and hotplate (see 2.1).
Remove the fixing screws from the front of the oven
multi-function switch. Disconnect the leads and remove
the switch.
Fit the new switch.
Fig.9-6
Fig.9-5