5.0 SPECIFICATION
5.1 Model Number covered in this group of products
G3800
800mm wide manual lift gas Bratt Pan
G3800 DX
800mm wide manual lift gas Duplex Bratt Pan
5.2 Technical Data
TECHNICAL DATA – TABLE A
Gas Type
Natural
Propane
Injector diameters
Ø3.3mm
Ø2.0mm
Pilot Injectors
SIT 31.2
SIT 25
Supply Pressure
mbar
20
37
Inches w.g
8
14.8
Operating Pressure
mbar
10
34
Inches w.g
4
13.6
TECHNICAL DATA – TABLE B
HEAT INPUTS – NATURAL AND PROPANE GAS (kW net & Btu/hr gross)
MODEL NUMBER
G3800 & G3800DX
Total Input
kW 14
Btu/hr
52,545
TECHNICAL DATA – TABLE C
ELECTRICAL LOADING
MODEL NUMBER
G3800 & G3800DX
TOTAL POWER (kW)
0.02
Current (A) at 230V
0.1