IMPORTANT! 

 

 

  It is most important that these instructions be consulted before 

operating, installing and commissioning this appliance. Failure to 
comply with the specified procedures may result in damage or the need 
for a service call. 

 

  The installer must ensure that the installation of the appliance is in 

conformity with these instructions and National Regulations in force at 
the time of installation. Particular attention MUST be paid to: 

Gas 

Safety (Installation & Use) Regulations, Health and Safety at Work 
Act, Local and National Building Regulations, Fire Precautions 
Act.

 

 

 

TO PREVENT SHOCKS, ALL APPLIANCES MUST BE EARTHED. 

 

  This equipment is 

ONLY FOR PROFESSIONAL USE

, and shall be 

operated by 

QUALIFIED

 persons. It is the responsibility of the 

Supervisor or equivalent to ensure that users wear 

SUITABLE 

PROTECTIVE CLOTHING

 and to draw attention to the fact that, some 

parts will, by necessity, become 

VERY HOT

 and will cause burns if 

touched accidentally. 

 

  Upon receipt of the Instruction manual, the installer must instruct the 

responsible person(s) of the correct operation and maintenance of the 
appliance.  

 

  If a need arises to convert the appliance for use with another gas, a 

competent person must be consulted. Those parts which have been 
protected by the manufacturer 

MUST NOT

 be adjusted by the user. 

 

  Unless otherwise stated, parts which have been protected by the 

manufacturer are not to be adjusted by the installer. 

  

 Regular 

servicing 

by 

a qualified person is recommended to ensure the 

continued safe and efficient performance of the appliance. 

 

  Care must be taken to control the movement of an appliance fitted with 

castors. 

 

 

 

 

 

Summary of Contents for Dominator Plus G3800

Page 1: ...USERS INSTALLATION AND SERVICING INSTRUCTIONS GAS BRATT PAN G3800 and G3800DX T100753 Rev 3 Published 04 10 2012 DATE PURCHASED MODEL NUMBER SERIAL NUMBER DEALER SERVICE PROVIDER...

Page 2: ...01438 363 000 SYMBOLS PLEASE READ THIS MANUAL This manual should be read carefully before operating installing or servicing the appliance WARNING Please pay particular attention to sections of the man...

Page 3: ...Technical Data 9 6 0 DIMENSIONS CONNECTION LOCATIONS 10 7 0 INSTALLATION 11 7 1 Unpacking 11 7 2 Siting Clearances 11 7 3 Ventilation 12 7 4 Gas Supply Connection 12 7 5 Electric Supply Connection 12...

Page 4: ...0 INTRODUCTION This appliance has been CE marked on the basis of compliance with the Gas Appliance Low Voltage and EMC Directives for the heat inputs gas pressures and voltages stated on the data pla...

Page 5: ...is the responsibility of the Supervisor or equivalent to ensure that users wear SUITABLE PROTECTIVE CLOTHING and to draw attention to the fact that some parts will by necessity become VERY HOT and wi...

Page 6: ...6 2 0 OPERATION 2 1 Controls...

Page 7: ...er neon will go out and the ignition sequence begins again repeat this stage as necessary 6 When the desired temperature is reached the green neon will go out 7 If cooking a liquid based food ensure i...

Page 8: ...ON Failure due to lack of proper cleaning is not covered by warranty BEFORE ANY CLEANING IS UNDERTAKEN ENSURE THE APPLIANCE IS UNPLUGGED FROM THE MAINS SUPPLY AND CANNOT BE INADVERTENTLY TURNED ON WAR...

Page 9: ...atural Propane Injector diameters 3 3mm 2 0mm Pilot Injectors SIT 31 2 SIT 25 Supply Pressure mbar 20 37 Inches w g 8 14 8 Operating Pressure mbar 10 34 Inches w g 4 13 6 TECHNICAL DATA TABLE B HEAT I...

Page 10: ...10 6 0 DIMENSIONS CONNECTION LOCATIONS...

Page 11: ...igure given for individual appliances instructions If a Gully is used in the premises ensure there is a gap of 200mm between the gully and front of the appliance DO NOT directly connect the flue to an...

Page 12: ...ith IGE UP 2 The pipe work should be of adequate size but not smaller than unit gas inlet connection i e Rp B S P An isolating cock must be located close by to allow shut down during an emergency or s...

Page 13: ...elevant figures refer to section 5 2 1 Turn appliance on and ensure red neon illuminates 2 Turn water tap on and ensure it is working correctly without any leakage 3 Ensure the pan tilting handle is f...

Page 14: ...TE Ensure gas supply is disconnected before commencing Only reconnect gas supply after all conversion work has been completed Burner and pilot Injectors a Remove front panel b Remove burner injector c...

Page 15: ...ENSURE THAT IT PERFORMS CORRECTLY AND CARRY OUT ANY NECESSARY ADJUSTMENTS AS DETAILED IN COMMISSIONING Symbols on drawings denotes a pozi head screw requires removal denotes a flat head screw requires...

Page 16: ...16 5 6 7 When removing the front fascia care should be taken not to damage the neon cables...

Page 17: ...G THERMOSTAT The operating thermostat is located on the pan underside To replace remove the phial clamp from the underside of the pan by removing the two nuts Pull out thermostat phial and feed it dow...

Page 18: ...TAT Safety thermostat is located on the underside of the pan Push the button protruding out from the bottom of the box to reset To replace remove as per the operating thermostat Pull out phial then re...

Page 19: ...S Lift pan fully up to get access to the burner Access to the burner pipe is from the front of the appliance while the front panel is removed To replace the burner first the pipe must be removed The p...

Page 20: ...20 9 1 Wiring Diagram...

Page 21: ...21 9 2 Circuit Diagram...

Page 22: ...r and clean if dirty Low mains gas pressure Check with gas supplier Gas supply isolated off Restore supply Check with gas supplier Amber neon lighting multiple times Air in gas pipes happens after dis...

Page 23: ...s appliance we would recommend that a maintenance contract be arranged with SERVICELINE Visits may then be made at agreed intervals to carry out adjustments and repairs A quotation will be given upon...

Page 24: ...ms Gas water and electrical supply external to appliance Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an...