10.0 FAULT FINDING
FAULT
POSSIBLE CAUSES
REMEDY
Red neon not lighting.
No power from the supply.
Restore supply.
Faulty mains supply cord.
Replace supply cord.
Faulty neon
Replace neon
Green neon not lighting but
Red neon is on.
Tilt Switch not activated or
faulty.
Ensure pan is lowered in the
fully down position.
Operating thermostat
Check connections. If faulty,
replace.
Faulty Neon
Replace operating
thermostat.
Operating Thermostat out of
calibration.
Slow/Poor heating.
Valve pressure wrong
Check pressure and adjust if
necessary.
Burner ports blocked
Check burner and clean if
dirty.
Low mains gas pressure
Check with gas supplier
Gas supply isolated/off
Restore supply
Check with gas supplier
Amber neon lighting multiple
times
Air in gas pipes (happens
after disconnection or first
connection)
Gas will slowly bleed out
while attempting to ignite the
pilot
Safety thermostat tripped or
faulty
Reset safety thermostat or
replace if necessary
11.0 SPARE PARTS
MAIN SPARES LIST
PART NAME
SPARES NUMBER
Gas valve
535270011
Operating thermostat
731910500
Safety thermostat
732150006
Pilot assembly
536300048
Red neon
730962010
Amber neon
730962040
Green neon
354510270
When ordering spare parts please quote the following;
Appliance type
Serial number
Gas Type
This information will be found on data plate attached to base plate.