Checkpoint
Okay
Not OK Not okay, solution:
Remarks:
Electrical
Check the conditions of all wiring and connections in the
lift.
Replace broken parts, leave this to a professional
mechanic.
Check the functioning of the main power switch.
Replace the wire connections or switch if necessary.
Check the functioning of all control buttons
Replace control buttons/panel if necessary.
Check all electrical wiring for signs of wear and tear,
kinks and connection.
Replace broken wiring/connections.
Check the functioning of the upper limit switch.
Adjust the upper limit switch of replace if necessary.
Other
Check if the manual is complete.
Contact your Falco retailer or the previous owner.
Check if the maintenance/examination legenda is kept
up to date.
Contact the previous owner.
Check if all warning- and safety stickers are readable
and complete.
Replace the stickers by original Falco stickers.
Check if the type plate is in place and readable.
Replace the type plate with an original Falco type plate
with correct serial number.
Check if the maximum capacity sticker is in place and
readable.
Place a new sticker with the correct maximum capacity
indication (3000kg).
Check if all control buttons are clearly recognizable, the
difference between lifting and lowering must be
recognizable at all times.
Replace the stickers for indication of the control buttons
by original Falco stickers.
Check the cleanliness of the work area under and
around the lift.
Clean the work area and remove obstacles out of the
safety zone.
Check if the safety zone around the lift is marked, the
safety zone should meet the standards described in
chapter 3.
Mark the safety zone.
All these checkpoints have to be checked every three months! Once a year they need to be inspected by an authorized company and/or specialized
person. Every check/inspection has to be registered in the included maintenance/inspection legenda.