40
The below figures depict alternate types and locations of the diverter valve and check/isolation valve. Non-draining configurations should be manually drained for
winter, self-draining systems do not require draining for winterization.
Acceptable Installation of Valves
APPENDIX E
—
Alternate Methods of Compliance
180° Actuator
Non Positive
Valve is Self
Draining
90° Actuator
Requires Manual
Draining
To
Pool
To
Solar
From
Pool
To
To
Solar
From
Pool
To
Pool
To
Solar
From
Pool
To
Solar
From
Pool
To
Pool
SOLAR OFF
SOLAR ON
SOLAR OFF
SOLAR ON
Figure 28| Diverter Valve on Supply, Isolation on Return
Aux
Heater
(optional)
Pool
Chlorinator
(optional)
Filter
Pump
Check
Valve
Diverter
Valve
Isolation
Valves*
Solar Drain
Valves
(optional)
Automation
Equipment
(recommended)
To
Solar
From
Solar
Outlet
Tee
Solar
Bypass
To
Pool
*Installing an isolation valve on the return line has the potential to deadhead the system if closed and supply valve is left open while operating