Closing Checklist
It is critical to the performance and longevity of the system that the following requirements be met:
The centermost collector in a bank should be “Fix
-
Mounted” so that the rest of the bank moves about the
centermost collector (Fix-Mounted Panel may be located elsewhere if governed by another factor)
Each SunSaver
®
Collector is mounted and spaced to allow for thermal expansion and contraction
Penetrations must be centered between collectors when system is running at operating temperatures
The SunSaver
®
system must be capable of draining (if not, manual drain valves should be installed or a
winterization service must be in place)
All plumbing in the system must hold under pressure without leaking
All plumbing in the system utilizes a standard method to allow for thermal movement
If used, all Flexible PVC lines are thoroughly protected from UV exposure by paint, wrapping or other
Non draining plumbing is able to be manually drained
There must be a VRV installed at the highest elevation in the plumbing for each major roof line/pitch