LAYOUT OF THE INSTALLATION - WIRING DIAGRAM AND ACCESSORIES
Before installing Fibo 300 or Fibo 400 prepare all the command and safety accessories as required.
General layout: merely indicative, it is the installer’s care and responsibility to properly lay the tubes for the electrical connections.
2
3
4
5
6
7
8
9
10
11
12
13
15
8
3
14
1
11
9
10
4
230 V 50 H
z ±10%
n° 2x1
n° 2x1
n° 4x1
n° 4x1
n
° 2x1
R
G5
8
n
° 4x1
n
° 4x1,5
1 - Miri 4 flasher - code 4612L
with Birio A8 aerial - code 4601L
2 - Arpo 58 transmitter - code 5802L
3 - Mechanical cable-operated safety edge - code 2077L
4 - Fit 55 recess photocell projector - code 551L
5 - Chis 37 recess key-switch - code 371L
6 - 230 V - 50 Hz - 0,03 A magneto-thermal differential
circuit breaker (not supplied with the equipment)
(beyond 100 m increase cable section to 2,5 mm²)
7 - Junction box (not supplied with the equipment)
8 - Fit 55 recess photocell receiver - code 551L
9 - 0,5 m post - code 555L
10 - Post fixing base plate
and cover - code 554L
11 - Gate stop (mandatory, not supplied with the equipment)
12 - Gear rack code 2039L
13 - Fibo 300 or Fibo 400
with Elpro 37 HP electronic controller - code 7185L
and VIX 53/2 R plug-in receiver - code 5311L
14 - Arpo 58 receiver - code 5801L
15 - VIX 53/4 TR transmitter - code 5313GL
IMPORTANT: all the electrical equipment must be properly grounded.
!