FITTING THE GEAR RACK TO THE GATE

With heavy gates, the standard gear rack is to be double mounted and only the steel version 22x22 mm per bar is recommended. 
It is to be fitted using support angles (not included) which are to be firmly welded to the gate following these instructions:
• Weld the single bars into compact double modules as indicated in Pic. 11.
• The total length of the gear rack must be equal to the gate travel, including the parts taken by the limit switch striking plates,
  which are to be fastened on the rack itself.
• Provide a temporary setup for the gear rack on the gate and make sure there is a tip clearance of about 2 mm between the drive
  gear and the teeth of the bar.
• Make sure the gear rack is perfectly aligned all along the gate travel before welding it firmly: test the correct alignment by manually
  running the gate full track, Fibo 300 or Fibo 400 in disengaged mode, and make sure the drive gear turns smoothly without any
  friction or jerking.
• Once satisfied with the outcome of the first running test, firmly weld the gear rack as indicated.

INSTALLING THE LIMIT SWITCH STRIKING PLATES

Gate stop, ie. stop of the drive gear, occurs when either striking plate meets the respective limit switches. Therefore the striking 
plates are to be installed on the gear rack once the open/closed positions of the gate have been precisely assessed, ie. when the 
gate is at the end/limit of the open and close cycles as required: it is recommended that the limit switches be activated a few 
seconds earlier than the gate reaches the end of the travel where a complete stop is required (Pic.12).

Fibo 300
Fibo 400

Three-phase electromechanical geared motor

for sliding gates

2,0 m

50x50x6 angle bracket

for gear rack fixing

(not included)

When joining the gear rack bars

make sure the pitch is respected

by using a “counter-gear rack” 

2 mm tip clearance between

drive gear and gear rack

Single, galvanized
22x22 mm, m4 bars welded 
into one double module

Leave a clearance of
about 10 mm 

Limit switch

50x50x6 angle bracket

for gear rack fixing

(not included)

22x22 zinc-coated

double rack

Drive gear

Gear rack fitted
to the gate

Gear rack

"Counter-gear rack"

Zinc-coated 22x22

double gear rack

Drive gear

2

2

2 mm

22

22

Command limit switch
mounted on
Fibo 300 or Fibo 400

Striking plate
fastening screw

The striking plate is to
engage the limit switch
feeler

Limit switch feeler

Command limit switch
mounted on
Fibo 300 or Fibo 400

Limit switch 
striking plate

LATERAL VIEW

Summary of Contents for FIBO 300

Page 1: ...ical operators for heavy industrial sliding gates Fibo 300 1 5 HP maximum gate weight 2 500 kg Fibo 400 3 0 HP maximum gate weight 4 000 kg 1 12 GB Instructions manual pages FIBO 300 FIBO 400 FIBO 300...

Page 2: ...ning about the presence of an automated installation The installer must inform and instruct the end user about the proper use of the system by releasing him a technical dossier including layout and co...

Page 3: ...y lead into the gate going off the rail during its opening closing travels NOTE WELL make sure that proper gate stops be fixed to ground in open and closed gate positions to prevent the gate from over...

Page 4: ...rator fixing base plate Electric motor Release box spanner E 23 27 Drive gear Metal protection cover Cover fixing screws with washers Command limit switch Gear box Pre bored operator fixing base plate...

Page 5: ...al geared motor for sliding gates NOTEWELL in doing this operation the door is no longer supported by the cover and might fall down remove it from its seat along with the cover IMPORTANT to achieve fi...

Page 6: ...led Overriding for manual operations is by the spanner supplied with the equipment and the release system is positioned in the front side of Fibo 300 or Fibo 400 on the drive gear shaft unlock the M18...

Page 7: ...stop of the drive gear occurs when either striking plate meets the respective limit switches Therefore the striking plates are to be installed on the gear rack once the open closed positions of the g...

Page 8: ...code 5802L 3 Mechanical cable operated safety edge code 2077L 4 Fit 55 recess photocell projector code 551L 5 Chis 37 recess key switch code 371L 6 230 V 50 Hz 0 03 A magneto thermal differential cir...

Page 9: ...the operator torque to the gate weight turn the self locking nut positioned on the operator base screw the nut harder to increase torque unscrew to decrease torque Pic 14 and Pic 15 English Fibo 300...

Page 10: ...orque 300 Nm 50 Hz 247 Nm 60 Hz Transfer speed 1 400 rpm 50 Hz 10 5 m 1 Transfer speed 1 700 rpm 60 Hz 12 8 m 1 Hydraulic oil type Oil Fadini art 706L Working temperature 25 C 80 C Fibo 300 weight 65...

Page 11: ...Transfer speed 1 700 rpm 60 Hz 12 8 m 1 Hydraulic oil type Oil Fadini art 706L Working temperature 25 C 80 C Fibo 400 weight 105 kg Maximum gate weight 4 000 kg Protection standard IP 55 inside the e...

Page 12: ...motor for sliding gates 2018 04 Via Mantova 177 A 37053 Cerea VR Italy Ph 39 0442 330422 Fax 39 0442 331054 info fadini net www fadini net GB 2012 19 UE Directive Re disposal of electric and electroni...

Page 13: ...No 92 3 Colombo Road Katuwawala Local Exclusive Partner for Sri Lanka Maldives Boralesgamuwa Sri Lanka info leadingway lk www leadingway lk T 94 0 115288856 8 F 94 0 11 4835334 R...

Reviews: