Pic. 6
Pic. 5
Pic. 4
5
E
n
g
li
sh
INSTALLING FIBO 300 AND FIBO 400
Removing the cover - Fibo 300 and Fibo 400:
The first installation step is to bare the motor operator. To do this, undo the four
lateral screws and pull the cover upwards (Pic. 4).
Next step. Undo the fixing screws of all the components indicated in Pic. 2 and in
Pic. 3, then proceed with the installation.
Positioning the base plate - Fibo 300 and Fibo 400:
Once satisfied with the correct position where Fibo 300 or Fibo 400 should be
installed next to the gate, respect the installation distances as in Pic. 5 and Pic. 6.
Mark the paving in correspondence with the four holes in the base plate, remove
Fibo 300 or Fibo 400, drill and insert the anchoring expanding bolts.
Fibo 300
Fibo 400
Three-phase electromechanical geared motor
for sliding gates
!
NOTE WELL: in doing this operation the door is no longer supported
by the cover and might fall down: remove it from its seat along with
the cover.
!
IMPORTANT: to achieve firm anchoring of the Fibo 300 or Fibo 400
assess the ground first and make sure it is adaquate to provide a firm
anchoring for the motor so it can properly operate a heavy gate.
Basa plate
Cover fixing
screws with washers
Protection
cover
!
!
Wall
65 mm
Ø 16
500 mm
80 mm
500 mm
Ø 50 hole for
cable inlet
Drill and fit the
expanding bolts
(not included)
Ø 16
Ø 50 hole for
cable inlet
Drill and fit the
expanding bolts
(not included)
Gate
Fibo 300
Base plate
Fibo 300
Wall
Gate
Fibo 400
Base plate
Fibo 400
Make sure soil is adequate to provide a firm
anchoring for the Fibo 300
NOTE WELL: the holes in the base
plate are factory-made
!
!
Make sure soil is adequate to provide a firm
anchoring for the Fibo 400
NOTE WELL: the holes in the base
plate are factory-made
350
290
430
280