8

PIC. 17

PIC. 16

PIC. 15

DIP-SWITCH B

Now commence the electrical work. Connect the control panel
ELPRO 13 exp as per pictures 16 and 18.

Important

: Should N.C. contacts eg. Photocells, Stop Button and

safety contact not exist, link out individually. If the operators run in
wrong direction reverse 17, 18 or 20, 21 respectively.
Once the connections have been made, set the dip-switch "B" as
required but with No. 3 "ON" automatic, pulse the radio transmitter or
short out terminals 7 - 8 momentarily and make sure that the operating
run and dwell times are as required, adjust through the rotary timers
7-8-9. See diagram ELPRO 13 exp. Picture 18.
The electrical equipment must be properly earthed.
Picture 17 shows an exemplary complete installation.

N.W.: CARRY OUT A RISK ANALYSIS IN COMPLIANCE WITH EN 12445
AND EN 12453 NORMS AND FIT ANY SAFETY DEVICE WHERE
REQUIRED.

n

°

2x1

n

°

4x1,5

n

°

4x1,5

n

°

4x1

n

°

4x1

n

°

4x1

n

°

2x1

n

°

4x1

n

°

3x1,5

n

°

2x1

11

12

13

14

1

2

3

4

5

6

7

8

9

10

15

16

16

®

DAMPENING

DAMPENING DEVICE

OUT OF SERVICE

IN SERVICE

OIL FILLER CAP

JUNCTION BOX

CUT OUT BRICKWORK
TO PROVIDE PROTECTION
FOR THE CONTROL BOX

Should the model with the dampening device be required to install
adjustment in the open and close cycles is by means of a screw
on the top of the jack end cap: with a screwdriver give one turn
clockwise. The dampening device is now in service and the gate
will "brake", ie. slow down speed over the last 40 cm of its angular
motion. One turn anti-clockwise will re-set to the standard operating
mode. Picture No. 15.

ELECTRIC P.C. BOARD

1 - MAINS SWITCH 230V - 50Hz

        MAGNETIC-THERMAL DIFFERENTIAL 0.03A
       (CABLES LONGER THAN 100 m ø 2,5 mm)
   2 - JUNCTION BOX
   3 - COMBINED JACK/MOTOR PUMP LEFT-HANDED
   4 - CLOSED GATE STOP REQUIRED
   5 - COMBINED JACK/MOTOR PUMP

   RIGHT-HANDED

   6 - POST WITH PHOTOCELL RECEIVER POLO 44
   7 - POST WITH PHOTOCELL PROJECTOR POLO 44
   8 - KEYSWITCH PRIT 19
   9 - PHOTOCELL RECEIVER POLO 44

10 - PHOTOCELL TRANSMITTER POLO 44
11 - FLASHING LAMP MIRI 4
12 - AERIAL BIRIO A8
13 - RADIO RECEIVER ASTRO 43/1 R
14 - CONTROL BOX ELPRO 13 exp
15 - RADIO TRANSMITTER ASTRO 43/2 TR SMALL
16 - OPEN GATE STOP REQUIRED

NOTE WELL

: EARTH CONNECT THE WHOLE SYSTEM

Summary of Contents for COMBI 740

Page 1: ...B Instruction manual COMBI 740 Oil hydraulic operator for swinging gates Below ground Version with two way locking device Version with brake in open close cycles Version with 110 and 175 shaft rotatio...

Page 2: ...RE VALVE CLOSE SAFETY PRESSURE VALVE OPEN VALVE COVER TWO WAY LOCKING VALVE ASSEMBLY MOTOR END PART MOTOR END PART PUMP SHAFT MOTOR BASE FLANGE SUCTION FILTER OIL RESERVOIR ELECTRIC MOTOR HYDRAULIC LO...

Page 3: ...IL RESERVOIR PLUG OIL RESERVOIR END CAP WIRE CONNECTORS HYDRAULIC OIL ARNICA A 15 BY AGIP ELECTRICAL CABLE RIGHT HAND JACK END CAP DAMPENING ADJUSTMENT ELBOW JOINT BEARING TOOTHED MAIN SHAFT CENTRAL B...

Page 4: ...6 LH 747 LH 746 RH 747 RH GATE SPACER HINGES NYLON WIRE It is recommended to keep to these instructions to install the equipment in the correct way to get a perfect working system Electro hydraulic op...

Page 5: ...close to the gate post dimensions as indicated in picture No 5 and lay the enclosure in it perfectly horizontal with the help of a level The upper edge of the enclosure must be levelled with the pavem...

Page 6: ...IN RELEASED POSITION OR NON LOCKING GATE FIXING PLATE WITH SHAFT FITTING COLLAR BOX SPANNER LONG BOLTS COMBI 740 SB RELEASE Once satisfied that everything has been done as described so far make sure...

Page 7: ...prevent misuse See pictures No 12 13 With single gates the electric lock is to be installed horizontally in the most suitable way to meet the application requirements Double gates can be fitted with a...

Page 8: ...AMPENING DAMPENING DEVICE OUT OF SERVICE IN SERVICE OIL FILLER CAP JUNCTION BOX CUT OUT BRICKWORK TO PROVIDE PROTECTION FOR THE CONTROL BOX Should the model with the dampening device be required to in...

Page 9: ...OR RUN OPEN CLOSE TIME CAPACITORS MICROPROCESSOR DIP SWITCH TERMINAL FOR CONNECTIONS TO PUSH BUTTONS PULIN 3 1 AMP FUSE 24 V OUTPUT TERMINALS 12 13 TIMER SWITCHES FUSE 630 mA FUSE 5 AMPS 1 st CHANNEL...

Page 10: ...Hz CONDENSER 12 5 F RED YELLOW GREEN BLUE RED CONNECT THE ENCLOSURE EARTH WIRE 2 1 3 10 PIC 21 PIC 20 SPECIAL VERSIONS FLOW REGULATORS FOR COMBI 740 MANUAL TEST FOR COMBI 740 ADJUSTMENT SCREW FLOW REG...

Page 11: ...HYDRAULIC PUMP Pump flow rate P3 0 85 l min Working pressure 1 MPa 10 bars Max pressure 3 MPa 30 bars Working temperature 20 C 80 C Rotation time 110 23 s Oil type A 15 FADINI by AGIP Shaft rotation a...

Page 12: ...TOTAL QUALITY CONTROL system which ensures constant quality standards updated knowledge of the European Standards and compliance with their requirements in view of an ever increasing process of impro...

Reviews: