PRODUCT FEATURES

• Pre-oiled and pre-set for immediate installation.
• Close proximity of pump and jack gives fast response.
• Close pivot point (45 mm) to gate pier.
• Manual release from inside and outside of property.
• Choice of 110

°

 or 175

°

 rotation angle.

• Braking or non-braking versions available.
• Locking or non-locking versions available.
• Conforming to EN 12453, EN 12445 safety standards.
• All-in-one pump and jack unit, contained in a single enclosure, is

sunk into the ground at the foot of the left-hand and right-hand
gate to achieve synchronised operation. The unit should be piped
into a soak-away to allow for water drainage.

WARNINGS

- Before installing the equipment carry out a 

Risk

Analysis

 and fit any required device in compliance

with EN 12445 and EN 12453 Safety Norms.

- Should the combined unit jack/hydraulic motor pump

be removed for maintenance, servicing or repair,
disconnect the electric motor cable from the junction
box.

- Never cut off the cable from the electric motor.
- Make sure that the oil plug is properly tightened.
- Do not throw away oil from repaired or serviced units,

waste oil must be disposed of properly through a
specialised company.

- Do not throw away packaging such as cardboard,

polystyrene and nylon, which must be disposed of
properly through a specialised company.

- The electrical equipment must be properly earthed.

* Best performance can only be achieved by keeping to these

instructions.

The growth of MECCANICA FADINI has always been based
on the development of guaranteed products thanks to our
“TOTAL QUALITY CONTROL” system which ensures constant
quality standards, updated knowledge of the European
Standards and compliance with their requirements, in view
of an ever increasing process of improvement.

Meccanica Fadini recommends the control panel 

ELPRO 13 CEI

 to

achieve an installation that is in conformity to the existing safety
standards as illustrated in our chart.
The electronic programmer ELPRO 13 incorporates and can provide
all the functions which are required by the most demanding
applications with swinging gates.
In addition to the standard features of ELPRO 9 (Drwg. No. 1310) the
following requirements can be provided: “stroke reversing pulse”,
pedestrian mode, stop in any gate position by holding down the
remote control button. Among the added features and improvements
of ELPRO 13 in conformity to the European safety standards, there
is the mains rotary switch: it is fitted to the box cover and switches
off the mains voltage whenever the cover is removed.

The “CE” mark certifies that the operator conforms to the essential
requirements of the European Directive art. 10 EEC 73/23, in relation
to the manufacturer’s declaration for the supplied items, in
compliance with the body of the regulations ISO 9000=UNI EN 29000.
Automation in conformity to EN 12453, EN 12445 safety standard.

CHECKING AND MAINTENANCE

:

To achieve an optimum performance and longer life of the
equipment and in observance of the safety regulations, it
is recommended that inspections and proper maintenance
are made by qualified technicians to the whole installation
ie. both the mechanical and electronic parts, as well as
wiring.
- Mechanical parts: maintenance every 6 months approx.
- Electronic apparatus and safety equipment: maintenance

inspection monthly.

EUROPEAN MARK CERTIFYING CONFORMITY
TO THE ESSENTIAL REQUIREMENTS OF THE
STANDARDS 98/37/EC

• DECLARATION OF CONFORMITY
• SAFETY NORMS
• EN 12453, EN 12445 STANDARDS
• CEI EN 60204-1 STANDARDS
• WARRANTY CERTIFICATE ON THE CUSTOMER’S REQUEST

SINGLE-PHASE

CUT OFF MAINS SWITCH

Summary of Contents for COMBI 740

Page 1: ...B Instruction manual COMBI 740 Oil hydraulic operator for swinging gates Below ground Version with two way locking device Version with brake in open close cycles Version with 110 and 175 shaft rotatio...

Page 2: ...RE VALVE CLOSE SAFETY PRESSURE VALVE OPEN VALVE COVER TWO WAY LOCKING VALVE ASSEMBLY MOTOR END PART MOTOR END PART PUMP SHAFT MOTOR BASE FLANGE SUCTION FILTER OIL RESERVOIR ELECTRIC MOTOR HYDRAULIC LO...

Page 3: ...IL RESERVOIR PLUG OIL RESERVOIR END CAP WIRE CONNECTORS HYDRAULIC OIL ARNICA A 15 BY AGIP ELECTRICAL CABLE RIGHT HAND JACK END CAP DAMPENING ADJUSTMENT ELBOW JOINT BEARING TOOTHED MAIN SHAFT CENTRAL B...

Page 4: ...6 LH 747 LH 746 RH 747 RH GATE SPACER HINGES NYLON WIRE It is recommended to keep to these instructions to install the equipment in the correct way to get a perfect working system Electro hydraulic op...

Page 5: ...close to the gate post dimensions as indicated in picture No 5 and lay the enclosure in it perfectly horizontal with the help of a level The upper edge of the enclosure must be levelled with the pavem...

Page 6: ...IN RELEASED POSITION OR NON LOCKING GATE FIXING PLATE WITH SHAFT FITTING COLLAR BOX SPANNER LONG BOLTS COMBI 740 SB RELEASE Once satisfied that everything has been done as described so far make sure...

Page 7: ...prevent misuse See pictures No 12 13 With single gates the electric lock is to be installed horizontally in the most suitable way to meet the application requirements Double gates can be fitted with a...

Page 8: ...AMPENING DAMPENING DEVICE OUT OF SERVICE IN SERVICE OIL FILLER CAP JUNCTION BOX CUT OUT BRICKWORK TO PROVIDE PROTECTION FOR THE CONTROL BOX Should the model with the dampening device be required to in...

Page 9: ...OR RUN OPEN CLOSE TIME CAPACITORS MICROPROCESSOR DIP SWITCH TERMINAL FOR CONNECTIONS TO PUSH BUTTONS PULIN 3 1 AMP FUSE 24 V OUTPUT TERMINALS 12 13 TIMER SWITCHES FUSE 630 mA FUSE 5 AMPS 1 st CHANNEL...

Page 10: ...Hz CONDENSER 12 5 F RED YELLOW GREEN BLUE RED CONNECT THE ENCLOSURE EARTH WIRE 2 1 3 10 PIC 21 PIC 20 SPECIAL VERSIONS FLOW REGULATORS FOR COMBI 740 MANUAL TEST FOR COMBI 740 ADJUSTMENT SCREW FLOW REG...

Page 11: ...HYDRAULIC PUMP Pump flow rate P3 0 85 l min Working pressure 1 MPa 10 bars Max pressure 3 MPa 30 bars Working temperature 20 C 80 C Rotation time 110 23 s Oil type A 15 FADINI by AGIP Shaft rotation a...

Page 12: ...TOTAL QUALITY CONTROL system which ensures constant quality standards updated knowledge of the European Standards and compliance with their requirements in view of an ever increasing process of impro...