COMBI 740

45

DESCRIPTION

Ferrule with square hole
Shaft fitting collar welded to the gate fixing
plate

Emergency locking shoe complete with collar
and release spanner

DISTANCE A

30 mm

42 mm

70 mm

ITEM No.

702/5

746

748

125

DISTANCE 0,00

40

100

200

350

500

220

®

BRICKWORK

TOP HINGE PERPENDICULAR
TO THE CENTRE MARK HOLE

LEVEL

CENTRE MARK HOLE

PAVEMENT FINISH

PAVEMENT
UNDERNEATH LAYER

CONCRETE TO SUPPORT
THE ENCLOSURE

CONCRETE TO PROVIDE
A LEVEL BASE AT
A SET DISTANCE

SOIL

LAYER OF GRAVEL
FOR WATER TO
SOAK AWAY

SOAKAWAY PIPE TO BE
CONNECTED TO THE STORM DRAIN

BRICKWORK FOUNDATIONS

First of all make sure that the gates are
adequate to take the mechanism inspect all
the critical parts and see if they need
reinforcement or adjustment, specially those
parts which are most subject to friction such
as the upper hinge. Picture 4.
Dig a hole in the ground close to the gate post
(dimensions as indicated in picture No. 5) and
lay the enclosure in it perfectly horizontal
with the help of a level. The upper edge of
the enclosure must be levelled with the
pavement finish. Picture No. 7.

Important

: the centre line of the gate hinges

must coincide with the centre of the hole in
the bottom of the enclosure to provide a
reference mark for alignment. Suitable holes
are also provided in the enclosure for the
electric cable and soak away tube.
The distance from the top edge of the
enclosure to the pavement level (after
finishing all works) must be zero. Picture 6.

It is important that the full weight of the
gates is directly on the gate operator. Also
that only a top hinge is used.

TOP HINGE

FIXING SCREWS

CABLE OUTLET

SOAKAWAY PIPE

GRAVEL

BRICKWORK PILLAR

HOLE

GATE HINGE

PAVEMENT FINISH

CENTRE LINE PERPENDICULAR
TO THE REFERENCE MARK

WEDGE THE ENCLOSURE FOR ALIGNMENT AND
BRING THE UPPER EDGE TO THE REQUIRED LEVEL

THE CENTRE OF THIS
HOLE TO COINCIDE
WITH THE HINGE
CENTRE LINE

MINIMUM DISTANCE ALLOWED

SHAFT FITTING COLLAR 702/5

DISTANCE 

A

CONCRETE

Summary of Contents for COMBI 740

Page 1: ...B Instruction manual COMBI 740 Oil hydraulic operator for swinging gates Below ground Version with two way locking device Version with brake in open close cycles Version with 110 and 175 shaft rotatio...

Page 2: ...RE VALVE CLOSE SAFETY PRESSURE VALVE OPEN VALVE COVER TWO WAY LOCKING VALVE ASSEMBLY MOTOR END PART MOTOR END PART PUMP SHAFT MOTOR BASE FLANGE SUCTION FILTER OIL RESERVOIR ELECTRIC MOTOR HYDRAULIC LO...

Page 3: ...IL RESERVOIR PLUG OIL RESERVOIR END CAP WIRE CONNECTORS HYDRAULIC OIL ARNICA A 15 BY AGIP ELECTRICAL CABLE RIGHT HAND JACK END CAP DAMPENING ADJUSTMENT ELBOW JOINT BEARING TOOTHED MAIN SHAFT CENTRAL B...

Page 4: ...6 LH 747 LH 746 RH 747 RH GATE SPACER HINGES NYLON WIRE It is recommended to keep to these instructions to install the equipment in the correct way to get a perfect working system Electro hydraulic op...

Page 5: ...close to the gate post dimensions as indicated in picture No 5 and lay the enclosure in it perfectly horizontal with the help of a level The upper edge of the enclosure must be levelled with the pavem...

Page 6: ...IN RELEASED POSITION OR NON LOCKING GATE FIXING PLATE WITH SHAFT FITTING COLLAR BOX SPANNER LONG BOLTS COMBI 740 SB RELEASE Once satisfied that everything has been done as described so far make sure...

Page 7: ...prevent misuse See pictures No 12 13 With single gates the electric lock is to be installed horizontally in the most suitable way to meet the application requirements Double gates can be fitted with a...

Page 8: ...AMPENING DAMPENING DEVICE OUT OF SERVICE IN SERVICE OIL FILLER CAP JUNCTION BOX CUT OUT BRICKWORK TO PROVIDE PROTECTION FOR THE CONTROL BOX Should the model with the dampening device be required to in...

Page 9: ...OR RUN OPEN CLOSE TIME CAPACITORS MICROPROCESSOR DIP SWITCH TERMINAL FOR CONNECTIONS TO PUSH BUTTONS PULIN 3 1 AMP FUSE 24 V OUTPUT TERMINALS 12 13 TIMER SWITCHES FUSE 630 mA FUSE 5 AMPS 1 st CHANNEL...

Page 10: ...Hz CONDENSER 12 5 F RED YELLOW GREEN BLUE RED CONNECT THE ENCLOSURE EARTH WIRE 2 1 3 10 PIC 21 PIC 20 SPECIAL VERSIONS FLOW REGULATORS FOR COMBI 740 MANUAL TEST FOR COMBI 740 ADJUSTMENT SCREW FLOW REG...

Page 11: ...HYDRAULIC PUMP Pump flow rate P3 0 85 l min Working pressure 1 MPa 10 bars Max pressure 3 MPa 30 bars Working temperature 20 C 80 C Rotation time 110 23 s Oil type A 15 FADINI by AGIP Shaft rotation a...

Page 12: ...TOTAL QUALITY CONTROL system which ensures constant quality standards updated knowledge of the European Standards and compliance with their requirements in view of an ever increasing process of impro...

Reviews: