background image

11

COMBI 740 TECHNICAL SPECIFICATIONS

PIC. 22

Via Mantova, 177/A - 37053 Cerea (VR) Italy - Tel. 0442 330422 r.a. - Fax 0442 331054

®

s.n.c.

®

A

140

140

470

235

235

300

45

35

ø 12

190

B

190

50

10

40

50

35

30

C

®

A

  The combined motor and jack of the COMBI 740 employs

the latest technology with a quiet-running steel lobe pump
at its heart, creating and holding greater pressures for
hydraulic locking and drive than most other underground
gate operators.

B

  Gate fixing device (locking version) is welded or screwed

to gate foot. Lock can be released by special key.

C

Gate fixing device (non locking version) is welded to gate

foot.

D

  Fix to the ground proper gate stops both in the open and

closed gate position. See page 7 in the installation manual.

Left-handed unit.
View from inside property.

Suitable for gate width from 2 up to 3.5 m max. with or without
locking/dampening depending on gate size and site requirements.

DOUBLE STROKE JACK AND OIL-HYDRAULIC PUMP

Pump flow rate - P3 ...........................................................0.85 

l

/min.

Working pressure ....................................................1 MPa (10 bars)
Max. pressure...........................................................3 MPa (30 bars)
Working temperature ....................................................–20

°

C +80

°

C

Rotation time (110

°

).......................................................................23 s

Oil type ..............................................................A 15 FADINI by AGIP
Shaft rotation angle .....................................................................110

°

Rated torque ............................................................................235 Nm
Cylinder bore .............................................................................75 mm
Stroke .........................................................................................52 mm
Weight with accessories ..........................................................27 Kg
Static gate weight ....................................................................700 Kg
IP Standards...............................................................................IP 673
Overall dimensions.................................................470x300x150 mm

DAMPENING

Pump flow rate - P3 ...........................................................0.85 

l

/min.

Rotation time (175

°

).......................................................................28 s

CLASS H, TWO-PHASE, ELECTRIC MOTOR

Power output .........................................................0.18 KW (0.25 HP)
Supply voltage................................................................230 V - 50 Hz
Absorbed current ........................................................................1.2 A
Absorbed power........................................................................250 W
Capacitor ...................................................................................12.5 

+

F

Motor rotation speed.......................................................1˙350 r.p.m.
Intermittent service........................................................................S 3

Duty cycle ................23 sec. Open - 30 sec. Dwell - 23 sec. Close
Time of one complete cycle ........................................................76 s
No. of complete cycles Open - Dwell - Close ....................47/hour
No. cycles a year, 8 hours a day ..........................................137˙000

0.25

1.2

50

12.5

MOTOR

W

VOLTS

r.p.m.

Nm

2 PHASE

250

230

1˙350

235

HP

A

Hz

+

F

Shaft ro. 110

°

 - 23 sec. - P3 - 0.85 

l

/min.

Shaft ro. 175

°

 - 28 sec. - P3 - 0.85 

l

/min.

Temperature –20

°

C  +80

°

C

Degree of protection IP 673

Working pressure max. 3 MPa (30 Bars)

OIL FADINI A15 BY AGIP

MADE IN ITALY

STICKER WITH ELECTRIC MOTOR SPECIFICATIONS

Summary of Contents for COMBI 740

Page 1: ...B Instruction manual COMBI 740 Oil hydraulic operator for swinging gates Below ground Version with two way locking device Version with brake in open close cycles Version with 110 and 175 shaft rotatio...

Page 2: ...RE VALVE CLOSE SAFETY PRESSURE VALVE OPEN VALVE COVER TWO WAY LOCKING VALVE ASSEMBLY MOTOR END PART MOTOR END PART PUMP SHAFT MOTOR BASE FLANGE SUCTION FILTER OIL RESERVOIR ELECTRIC MOTOR HYDRAULIC LO...

Page 3: ...IL RESERVOIR PLUG OIL RESERVOIR END CAP WIRE CONNECTORS HYDRAULIC OIL ARNICA A 15 BY AGIP ELECTRICAL CABLE RIGHT HAND JACK END CAP DAMPENING ADJUSTMENT ELBOW JOINT BEARING TOOTHED MAIN SHAFT CENTRAL B...

Page 4: ...6 LH 747 LH 746 RH 747 RH GATE SPACER HINGES NYLON WIRE It is recommended to keep to these instructions to install the equipment in the correct way to get a perfect working system Electro hydraulic op...

Page 5: ...close to the gate post dimensions as indicated in picture No 5 and lay the enclosure in it perfectly horizontal with the help of a level The upper edge of the enclosure must be levelled with the pavem...

Page 6: ...IN RELEASED POSITION OR NON LOCKING GATE FIXING PLATE WITH SHAFT FITTING COLLAR BOX SPANNER LONG BOLTS COMBI 740 SB RELEASE Once satisfied that everything has been done as described so far make sure...

Page 7: ...prevent misuse See pictures No 12 13 With single gates the electric lock is to be installed horizontally in the most suitable way to meet the application requirements Double gates can be fitted with a...

Page 8: ...AMPENING DAMPENING DEVICE OUT OF SERVICE IN SERVICE OIL FILLER CAP JUNCTION BOX CUT OUT BRICKWORK TO PROVIDE PROTECTION FOR THE CONTROL BOX Should the model with the dampening device be required to in...

Page 9: ...OR RUN OPEN CLOSE TIME CAPACITORS MICROPROCESSOR DIP SWITCH TERMINAL FOR CONNECTIONS TO PUSH BUTTONS PULIN 3 1 AMP FUSE 24 V OUTPUT TERMINALS 12 13 TIMER SWITCHES FUSE 630 mA FUSE 5 AMPS 1 st CHANNEL...

Page 10: ...Hz CONDENSER 12 5 F RED YELLOW GREEN BLUE RED CONNECT THE ENCLOSURE EARTH WIRE 2 1 3 10 PIC 21 PIC 20 SPECIAL VERSIONS FLOW REGULATORS FOR COMBI 740 MANUAL TEST FOR COMBI 740 ADJUSTMENT SCREW FLOW REG...

Page 11: ...HYDRAULIC PUMP Pump flow rate P3 0 85 l min Working pressure 1 MPa 10 bars Max pressure 3 MPa 30 bars Working temperature 20 C 80 C Rotation time 110 23 s Oil type A 15 FADINI by AGIP Shaft rotation a...

Page 12: ...TOTAL QUALITY CONTROL system which ensures constant quality standards updated knowledge of the European Standards and compliance with their requirements in view of an ever increasing process of impro...

Reviews: