CAS1000 – OVERFLOW DETECTION
The Flame Effect stops, you hear a beep and the
LED's
BLINK ONCE EVERY 8 SECONDS
on one side
of the product. The other side turns off
The product has detected an overflow of water
Lift off the Fuelbeds and set aside
Press the switch to the (0) off position
Product that is connected to mains water supply
Product uses the bottle to fill the sump
On both sides of the product, lift off the Nozzle and lift
out the sump. Check to see if in the off state water still
comes through the solenoid.
Possibly some grit has become lodged in the solenoid
valve. Using the test mode procedure, switch on the
solenoids to flush water through. If this does not fix the
problem then request a spare solenoid valve
Once the solenoid is replaced or flushed through re-
establish water to the product and reassemble the sump
and nozzle. Remove overflow of water in the sump to
return it to operating water level.
Lift out the bottle. Check that the bottle lid is intact. If
there is a problem with the lid then request a spare lid.
Fill the bottle with the newly fitted lid with water and
place it back onto the sump. Remove overflow of water in
the sump to return it to operating water level.
Press the switch to the (I) on position
You will hear one beep, Replace the fuelbed
Press On/Standby button on the; On Board controls, Receiver or
Remote Control
ps you
ected a
elbeds
h to th
the; O
On board controls (Slave)
On board controls (Master)
Remote Control
Bluetooth Receiver
The CAS1000 is
operating
normally
The CAS1000 is switched on and was operating normally
O
I
O
I
O
I
O
I
Summary of Contents for CAS500
Page 1: ......