CAS500 – OVERFLOW DETECTION
The CAS500 is switched on and was operating normally
The Flame Effect stops, you hear a beep and the
LED's
BLINK ONCE EVERY 8 SECONDS
The product detected an overflow of water
Lift off the Fuelbed and set aside
Press the switch to the (0) off position
Product is connected to mains water supply
Product uses the bottle to fill the sump
Lift off the Nozzle and lift out the sump
Check to see if in the off state water still comes through
the solenoid.
Possibly some grit has become lodged in the solenoid
valve. Using the test mode procedure, switch on the
solenoids to flush water through. If this does not fix the
problem then request a spare solenoid valve
Once the solenoid is replaced or flushed through re-
establish water to the product and reassemble the sump
and nozzle. Remove overflow of water in the sump to
return it to operating water level.
Lift out the bottle. Check that the bottle lid is intact. If
there is a problem with the lid then request a spare lid.
Fill the bottle with the newly fitted lid with water and
place it back onto the sump. Remove overflow of water in
the sump to return it to operating water level.
Press the switch to the (I) on position
You will hear one beep, Replace the fuelbed
Press On/Standby button on the;
On Board controls, Receiver or Remote Control
O b
d
Bluetooth
Receiver
Remote control
s you
an ove
uelbed
h to the
ndby b
On board controls
O
I
O
I
O
I
O
I
Product is operating
normally