9. Other Information
.20
9
Procedure following power failure
After any interruption to the electricity supply, the control unit automatically switches
back to the mode it was in before the outage.
Date and time...
...are retained for at least 3 days. If the interruption is longer they may have to be reset.
When the power is restored the control unit will automatically ask for this to be done.
Exception:
If the control unit was in cleaning mode, cooling starts again immediately
and only fault code (F34) is displayed.
Is the control
in cleaning mode ...
unit was
...as soon as power is restored, a draining period is run for the time in [n100] in order to
empty the tank.
ing then continues from the start of the
ing stage the
Clean
clean
system was in at the time of the power failure.
The tank monitor functions ...
...are maintained during a power failure, provided the optional power pack is installed
(see 8.15). Depending on the parameter settings, the fault code is also displayed
.21 Power pack (optional)
9
Installation:
Only the suitable original
-power pack may be connected.
Fabdec
Connect the power pack to terminals
+ (observe polarity)
40 41
The optional power pack offers enormous advantages for the
.
Gala-Kool Pro
The control unit's tank monitoring function is maintained in the event of a power cut.
During the outage fault code [F30] is displayed.
Maximum outage time during cooling exceeded
If in cooling mode a power outage lasts longer than the time set in [H20], fault code
(F6) flashes, followed by an alarm “DO NOT LOAD”.
IMPORTANT NOTE
The life of the rechargeable batteries is limited. Those fitted must be replaced by new
ones every two years at the latest.
Only (!)
of the following specification may be used:
rechargeable batteries
1.2 V NiMh - ize AA (min 2.000 mAh)
s
.
DO NOT USE
BATTERIES !!! EXPLOSIVE !!!
ORDINARY
Page 88