8. Setting of parameters
Setting milk times to monitor „cooling activated”
Range
Default
This function triggers an alarm if cooling has not been activated at the
entered milk times. This is to prevent to forget the activation of the cooling
in case of the first milking after the cleaning.
h41
1
milk time
00:00..23:59
--:--
h42
2
milk time
00:00..23:59
--:--
h43
3
milk time
00:00..23:59
--:--
Setting for monitor LOG files
h89 Recording additional information by Tank Monitor 0...3 0
0: deactivated
1: temperature 2
2: agitator - power monitoring
3: no function
Settings tank monitor LOG files
Range
Default
h90 Selection period (in days) of the recording data ( onsoft)
K
1 ..
365
90
h91 Logging intervals cleaning mode in minute
s
1 .. 10
2
h92 Logging intervals OFF and cooling mode in minutes
1 .. 30
15
Page 61