9. Other Information
9.17 Setting of a break in the cleaning programme
During the automatic cleaning programme it is possible to add a break after a cleaning
cycle.
Example: Setting a break after the pre-cleaning until sufficient quantities of warm
water from the heat recovery for the main cleaning cycle is available.
The following settings are necessary
After which cleaning cycle the break shall take place [r71]
How the break shall be finished [r70]
Options:
When the break should be finished ...
... via a signal at the digital input
assign the function 15 "Start from rinse stop" to a digital input A21 to A28.
... after a certain amount of time
enter this time in parameter [r72].
... at a certain time
enter them in parameter [r73].
A parameterized elapsed time of the break or the countdown-timer is displayed
alternately with “STOP”
9.18 Function test alarm
The function “test alarm” is required to test the impacts of an error on the
parameterized outputs in the F-parameters (relays, SMS etc.).
Method:
Set and store the configuration to be tested in parameter [F99]
Trigger test errors from the OFF mode by pressing buttons OFF and SET simulta-
neously for four seconds
Check if the required reaction has taken place
Reset the error triggered with the reset button
RESET
T1
T2
°C
OFF
SET
Page 86
Summary of Contents for CB2-1L120000
Page 29: ...Page 29 ...