Milk collection
Complete emptying of tank into collection tanker
Ensure that the green LED of the tank monitor indicator is lit
Press the OFF button
To stir the milk for a short period: briefly press the AGITATOR button. After the
desired stirring time, stop the agitator by pressing the OFF button.
Connect the milk pipe from the tanker.
Open the tank outlet. (depending on the system, either manually or by means
of the BUTTERFLY VALVE button)
If the tank has a pneumatic butterfly valve:
Press the “BUTTERFLY VALVE” button for approx. 3 seconds:
The butterfly valve opens – the milk is transferred to the tanker.
The “Valve open“ LED is lit.
When the tank is empty
Disconnect the tanker's milk pipe .
Connected the cleaning hose to the tank outlet.
Press the WASH button.
To draw off a small quantity of milk
(tanks with pneumatic butterfly valve)
If milk is to be taken from the tank while cooling mode is running, proceed as fol-
lows
Parameter [P32] Setting 1 -> Button function
The butterfly valve opens immediately and remains open for as long as the
button is held down.
When the button is released, the valve closes immediately.
Parameter [P32] Setting 2 -> Toggle function
-
Press the BUTTERFLY VALVE button for 3 seconds Outlet opens.
-
Briefly press the button again Outlet immediately closes.
For both settings a time limit can be programmed via parameter [P33].
5. Operation
Observe the tank monitor
The “Tank monitor” function indicates whether the milk quality is guaranteed or
whether a fault has occurred during cleaning.
LED shows green: milk can be taken out.
LED shows red: DO NOT LOAD MILK!
The fault is indicated in the display.
5.2.4 Operation of working level
OFF
Page 16
Summary of Contents for CB2-1L120000
Page 29: ...Page 29 ...