Range
Default
c25 Maximum continuous stirring period
0 .. 999 min.
30
in mode ‚continuous stirring‘
Setting of maximum continuous stirring period.
0:
indefinite stirring
)
(to end, the OFF button must be pressed
1..999: max. stirring period in minutes
Sensor correction adjustment
Range
Default
c90 Display actual temperature sensor 1
c91 Sensor correction sensor 1
10 .. 10 K
A correction can be applied to the value measured
by the sensor. Then applies it cumulatively
throughout the entire measurement range.
c92 Display actual temperature sensor 2
(hidden if A50 = 0)
c9 Sensor correction
3
sensor 2
-10 .. 10 K
(hidden if A50 = 0)
A correction can be applied to the value measured
by the sensor. Then applies it cumulatively
throughout the entire measurement range.
Software version
c98 Installed software version
The software version installed is shown to help
service technicians.
8. Setting of parameters
Page 45
Summary of Contents for CB2-1L120000
Page 29: ...Page 29 ...