background image

ENGLISH

CE CONFORMITY DECLARATION

Manufacturer: 

FAAC S.p.A.

Address:

 

Via Calari, 10  - 40069  Zola Predosa BOLOGNA - ITALY

Declares that: 

The control unit  

 
 

• ·conforms to the essential safety requirements of the following EEC directives 

 

  2006/95/EC Low Voltage Directive  

 

    99/5/EC  R&TTE

 

CE 0470

 

 

Additional note:

 

   

This product underwent tests in a typical homogenous configuration 

 

   

(all products manufactured by FAAC S.p.A.).

 

 

 

Bologna, 01 January 2010

 

   

 

 

 

 

The Managing Director

 

   

 

 

 

 

A.Marcellan

 

ATTENTION! To ensure the safety of people, it is important that 
you read all the following instructions. Incorrect installation 
or incorrect use of the product could cause serious harm 
to people.

  2)  Read the instructions carefully before installing the product.
  3)  Do not leave packing materials (plastic, polystyrene, etc.) within 

reach of children as such materials are potential sources of 
danger.

  4)  Store these instructions for future reference.
  5)  This product was designed and built strictly for the use indicated 

in this documentation. Any other use, not expressly indicated 
here, could compromise the good condition/operation of 
the product and/or be a source of danger.

  6)  FAAC declines all liability caused by improper use or use other 

than that for which the automated system was intended.

  7)  Do not install the equipment in an explosive atmosphere: the 

presence of inflammable gas or fumes is a serious danger 
to safety.

  8)  FAAC is not responsible for failure to observe Good Technique 

in the construction of the closing elements to be motorised, 
or for any deformation that may occur during use.

  9)  Before attempting any job on the system, cut out electrical 

power.

 10)  The mains power supply of the automated system must be 

fitted with an all-pole switch with contact opening distance 
of 3mm or greater. Use of a 6A thermal breaker with all-pole 
circuit break is recommended.

 11)  Make sure that a differential switch with threshold of 0.03 A is 

fitted upstream of the system.

 12)  Make sure that the earthing system is perfectly constructed, 

and connect metal parts of the means of the closure to it. 

 13)  The safety devices (EN 12978 standard) protect any danger 

areas  against 

mechanical  movement  Risks

,  such  as 

crushing, dragging, and shearing.

 14)  Use  of  at  least  one  indicator-light  (e.  g.:  FAACLIGHT)  is 

recommended for every system, as well as a warning sign 
adequately secured to the frame structure, in addition to 
the devices mentioned at point “15”. (if any)

 15)  FAAC declines all liability as concerns safety and efficient 

operation of the automated system, if system components 
not produced by FAAC are used.

 16)  For maintenance, strictly use original parts by FAAC.
 17)  Do not in any way modify the components of the automated 

system.

 18)  Do not allow children or adults to stay near the product while 

it is operating.

 19)  Keep  radio  controls  or  other  pulse  generators  away  from 

children,  to  prevent  the  automated  system  from  being 
activated involuntarily.

 20)  Transit is only possible when the automated system is idle.
 21)  The End-user must avoid any attempt to repair or adjust the 

automated  system  personally.  These  operations  must  be 
carried out exclusively by  qualified personnel.

 22)  Maintenance: perform at least every six months a functional 

check of the system, paying special attention to the efficiency 
of the safety devices (included, where foreseen, the operator’s 
thrust force) and of the release devices.

 23)  What  is  not  explicitly  stated  in  these  instructions  is  not 

permitted.

IMPORTANT NOTICE FOR THE INSTALLER

GENERAL SAFETY REGULATIONS

Summary of Contents for TM XA R 433

Page 1: ...TM XA R 433...

Page 2: ...ly of the automated system must be fitted with an all pole switch with contact opening distance of 3mm or greater Use of a 6A thermal breaker with all pole circuit break is recommended 11 Make sure th...

Page 3: ...presence of light Fig 1 Power supply 230 V 50 60 Hz Transmission frequency 433 72 Mhz Light sensor sensitivity 0 200 50 Klux Wind sensor sensitivity 5 60 Km h Use temperature 20 55 C Protection class...

Page 4: ...cure the anemometer to the wall using relevant screws and or dowels 6 Place again the anemometer cable in its correct seat Fig 6 ref e 7 Drill the cable bushing Fig 6 ref f and lead the power cable to...

Page 5: ...the three securing holes free Fig 10 ref f 6 Drill the securing holes for the anemometer on the wall in correspondence with its holes Fig 10 ref g 7 Secure the anemometer to the wall using the relevan...

Page 6: ...a a b d c c e f g ENGLISH Fig 8 Fig 9 Fig 10...

Page 7: ...n 10 seconds the programming push button for 2 seconds 3 Within 5 seconds press the STOP PREFERRED POSITION push button on the same remote control 4 Within 5 seconds simultaneously press both test pus...

Page 8: ...or operation the motor does not accept any command for 15 minutes At the end of this time if there is no wind and light is present the anemometer commands again a down movement of the rolling shutter...

Page 9: ...ovement of the rolling shutter if strong wind and low light are present and its up movement in the event of a light increase After the operation of the wind sensor the motor does not accept any comman...

Page 10: ...ind sensor activation sensitivity adjustment trimmer ifyouturnitclockwise theanemometer sends the commands to the associated motor with a higher wind intensity Sunsensoractivationsensitivityadjustment...

Page 11: ...is present the rolling shutter opens again Fig 25 Fig 26 6 DELETING THE ANEMOMETER FROM THE MOTOR MEMORY 1 Press twice the programming push button on an already memory stored remote control 2 Press s...