1) Remove both side screw covers (Fig.4 ref.
a
)
2) Remove the front cover after having removed the four
screw covers and the screws (Fig.5 ref.
b
)
3) Move the anemometer cable in order to have the
securing hole free. (Fig.5 ref.
c
)
4) Drill three securing holes for the anemometer on the wall
in correspondence with its holes (Fig.5 ref.
d
).
5) Secure the anemometer to the wall using relevant
screws and/or dowels.
6) Place again the anemometer cable in its correct seat (Fig.6 ref.
e
)
7) Drill the cable bushing (Fig. 6 ref.
f
), and lead the power cable to the terminals of the anemometer passing through
this hole (Fig.6 ref.
g
)
8) Be careful to place the rubber cable gland in its seat (Fig.6 ref.
h
)
9) Fit the cable tie supplied.
10) Turn the anemometer until reaching the desired angle (Fig.4 ref.
i
)
11) Tighten both side fastening screws and fit the covers (Fig.4 ref.
j
)