![background image](http://html1.mh-extra.com/html/faac/t-mode-tm-45-e/t-mode-tm-45-e_manual_3117238014.webp)
RESET
X 1
ENGLISH
14
4
seconds
1
second
1
second
HOLD THE BUTTONS PRESSED TILL THE MOTOR MAKES THE INDICATED MOVEMENTS
5 RESET
AT THE RESET, THE MOTOR IS RESTORED TO THE FACTORY SETTING. THIS OPERATION CAN BE PERFORMED AT ANY TIME, EVEN DUR-
ING THE SET-UP PROCEDURE.
1) Press the two buttons at the same time for 4 seconds
2) Release them for 1 second
3) Press them at the same time for 1 second
4) Release them for 1 second
5) Hold both buttons pressed till one short movement is performed in both directions, confirming the performed RESET
procedure:
1 second
6 ADVANCED MENU
6.1.1 MODIFYING THE SENSITIVITY OF THE OBSTACLE DETECTION WHEN LOWERING (ONLY FOR ROLLING SHUTTERS)
THE ADVANCED MENU CAN BE ACCESSED EXCLUSIVELY AFTER HAVING SET THE TRAVEL STOPS; IN THIS MENU IT IS POSSIBLE TO CHANGE
THE OBSTACLE DETECTION SENSITIVITY AND THE TORQUE IN THE LAST CENTIMETERS BEFORE THE UP TRAVEL STOP. TO EXIT
THE ADVANCED MENU, HOLD ONE OF THE TWO BUTTONS PRESSED TILL THE MOTOR MAKES 1 SHORT MOVEMENTS IN BOTH DIREC-
TIONS. TO BE SURE HAVING EXITED THE ADVANCED MENU, PRESS THE UP OR DOWN BUTTON AND CHECK THE LINEAR MOVEMENT
OF THE ROLLING SHUTTER.
1) Press the two buttons at the same time for 4 seconds.
2) Release them for 1 second.
3) Press them at the same time for 1 second.
4) Release them for 1 second.
5) Press them at the same time for 1 second.
6) Release them for 1 second.
7) Hold both buttons pressed till one short movement is performed in both directions, confirming the advanced menu
has been entered, and the motor makes three short movements in both directions.
8) Press twice the up and down buttons for 1 second at the same time and press them again at the same time till the
motor makes one short movement in both directions.
9) Press the up and down button N times for 1 second simultaneously to select the wished obstacle detection sensitivity
level (1 pressing - disabled obstacle detection .....10 pressings - max. obstacle sensitivity)
10) Press the up and down button at the same time till making 1 short movements.
11) If the motors makes three short movements in both directions, the correct procedure has not been performed and
you are still inside the advanced menu. Perform point 9 again.
Within 1 second
6.1 FUNCTIONS CONNECTED TO THE OBSTACLE DETECTION
The obstacle detection in the last centimetres before the travel limit is “inhibited”. If you wish to activate this function also
for that area, observe the operations described in chapter 6.1.2