x 2
x 2
x 1
ENGLISH
10
PRESS THE UP OR DOWN BUTTON AND TAKE THE ROLLING SHUTTER TO THE UP TRAVEL STOP
DURING THE SET-UP, DO NOT REVERSE THE MOTOR PHASES IN CASE OF OPPOSITE ROTATION OF THE ROLLING SHUTTER (FOR EX-
AMPLE PRESSING THE DOWN BUTTON THE MOTOR RISES THE AWNING). AT THE END OF SET-UP, THE UP/DOWN PUSH-BUTTONS ARE
AUTOMATICALLY MATCHED TO THE CORRECT ROTATION DIRECTION.
1) Press the up or down button and take the roller shutter to the wished position for the up travel stop; then, release the
button.
2) Press both buttons for 1 second
TWICE
, release them, and
hold them pressed till the motor makes two short move-
ments in both directions, to check the correct mode setting.
3) Press the button controlling the lowering and go to the down travel stop.
4) Press the up and down buttons at the same time till the motor makes one short movement in both directions.
5) Check if the positions of the set travel stops are correct. If the travel stops have not been set correctly, make a reset
and repeat the set-up procedure.
PRESS TWICE THE UP AND DOWN BUTTONS AT THE SAME TIME FOR 1 SECOND, RELEASE THEM FOR 0.5 SECONDS
AND PRESS AND HOLD BOTH BUTTONS PRESSED TILL THE MOTOR MAKES TWO SHORT MOVEMENTS IN BOTH
DIRECTIONS, TO CONFIRM THE STORING OF THE UP TRAVEL STOP.
PRESS THE UP OR DOWN BUTTON AND TAKE THE ROLLING SHUTTER TO THE DOWN TRAVEL STOP, RELEASE THE BUTTON
AND PRESS THE UP AND DOWN BUTTONS AT THE SAME TIME, TILL THE MOTOR MAKES ONE SHORT MOVEMENT IN
BOTH DIRECTIONS. THE SET-UP IS ENDED.
UP TRAVEL STOP
DOWN TRAVEL
STOP
OR
OR
4.3 SET-UP FOR UNIVERSAL AWNINGS (SPRING OR FALL TYPE)
Within 1 second
4.3.1 SET-UP FOR STANDARD AWNINGS STARTING FROM THE UP TRAVEL LIMIT
Summary of Contents for T-MODE TM 45 E
Page 1: ...T MODE TM 45 E TM 58 E...