x 1
x N
x 1
x 1
ENGLISH
18
within 1 second press and hold pressed
PRESS ONCE THE UP AND DOWN BUTTONS AT THE SAME TIME FOR 1 SECOND, RELEASE THEM FOR 1 SECOND
AND PRESS AND HOLD BOTH BUTTONS PRESSED TILL THE MOTOR MAKES ONE SHORT MOVEMENTS IN BOTH
DIRECTIONS,
1 up+down button pressing = 40% torque selected
2 up+down button pressings = 60% torque selected
3 up+down button pressings = 80% torque selected
4 up+down button pressings = 100% torque selected
Within 1 second
PRESS THE UP AND DOWN BUTTONS n TIMES FOR 1 SECOND SIMULTANEOUSLY, TO SET THE WISHED TORQUE,
RELEASE THEM FOR 1 SECOND AND PRESS AND HOLD BOTH BUTTONS PRESSED TILL THE MOTOR MAKES ONE SHORT
MOVEMENT IN BOTH DIRECTIONS, TO CONFIRM THE PERFORMED CHANGE AND THE EXIT FROM THE MENU.
6.3 DETECTING ICE ON THE GUIDES AND FITTED BOLTS DURING THE ROLLING SHUTTER RISE
The T-MODE motor with electronic travel limit is able to detect any
bolts fitted in the rolling shutter as well as the presence of ice on the
guides during the whole travel of the rolling shutter.
These events would
prevent the normal rise of the rolling shutter, thus damaging it.
When the rolling shutter is at rest, if you send a rise signal and the rolling
shutter stays at rest for 1 second due to the presence of bolts or ice on
the guides, the motor changes to stop status.
Summary of Contents for T-MODE TM 45 E
Page 1: ...T MODE TM 45 E TM 58 E...