background image

1257014-GB_v1.1 

STD-1EU / STD-2EU 

 

7

IMPORTANT SAFETY INSTRUCTIONS FOR USE 

• Do not allow children to play with the door controls. 

• Keep the remote controls out of the reach of children. 

• Watch the door movement and keep people away until the door is fully open or closed. 
• Precaution when operating the manual unlocking device, as the door may suddenly fall due to the 

bad condition of the springs or door unbalance. Details on how to use the manual unlocking device 

must be provided by the manufacturer or the device installer. 

• Examine the installation frequently, especially the cables, springs and supports, to detect signs of 
wear, damage or unbalance. Do not use the door if repair work or adjustments are required, as this 

may cause damage. 

 
 

USE OF THE EQUIPMENT 

This equipment is designed to automate garage doors following the general description. It is not 

guaranteed for other uses. The manufacturer reserves the right to modify equipment specifications 

without prior notice. 

 
 

CE DECLARATION OF CONFORMITY 

See website: www.jcm-tech.com 

 

Summary of Contents for STD-2EU

Page 1: ...ICS Panel supply 230V ac Power 3 4CV Optional cards Pluggable receiver card 2 channels 433 92 868 35 MHz and traffic light card Security device output 24V ac 0 75A and autotest Electro lock outlet 12V...

Page 2: ...Close motor 2 STANDARD 2 EU version 27 End of run Open motor 2 STANDARD 2 EU version 28 Common buttons 29 Pedestrian button NO 30 Start button NO 31 Close button NO 32 Common buttons 33 Stop button N...

Page 3: ...V Flash light contact DESTELLO Voltage free maintained contact to activate a Flash light max 250V 12A Electro lock ELECTRO 12V output timed for 2 seconds to activate an electric latch of a maximum of...

Page 4: ...ling Minimum Maximum Motor operating 3s 120s Wait for automatic close 3s 120s Gap between motors 0s 120s LIGHT INDICATORS Function Indicates Default status POWER Alimentation Normally on SEG Security...

Page 5: ...ps if the end of run has not been reached and the automatic standby timer begins When pressed for the fifth time the automatic standby timer stops and motor 2 is started to close When pressed for the...

Page 6: ...g the panel check that the door is in good mechanical condition correctly balanced and that it opens and closes correctly Install the manual unlocking device at a height lower than 1 8m Install any pe...

Page 7: ...ls on how to use the manual unlocking device must be provided by the manufacturer or the device installer Examine the installation frequently especially the cables springs and supports to detect signs...

Reviews: