Stop (PARO): Contact normally closed. This detains the operation on standby for a new order.
Where not used, turn option 5 on the input switch to ON.
Open (ABR.): Contact normally open to open. If it is pressed while the door is closing, it will stop
and open.
Close (CER.): Contact normally open to close. If it is pressed while the door is closing, it
will not be
triggered.
Pedestrian (PEA.): Contact normally open for partial opening. This acts only with motor 1.
Ends of run (FCC1 / FCA1 / FCC2 / FCA2): contacts normally closed to mechanically indicate the
open and closed end of run. Where not used, turn option 6, 7, 8 or 9 on the input switch to ON.
Security edge (BS.CE / BS.AB.): Resistive contact for resistive security edge. This acts on closing,
causing stoppage and inversion. This acts on opening, causing stoppage and inversion of 1s. Where
not used, turn option 3 or 4 on the input switch to ON.
Security contact (S.CER / S.ABR): Contact normally closed, photocell or magnetic detector type.
This acts on opening and closing, causing stoppage and inversion. Where not used, turn option 1 or
2 on the input switch to ON.
Garage light contact (LUZ GAR.): Voltage-free contact to activate an automatic light (max 100W to
230V
∼
).
Flash light contact (DESTELLO): Voltage-free maintained contact to activate a Flash light (max
250V / 12A)
Electro-lock (ELECTRO): 12V
=
output timed for 2 seconds to activate an electric latch of a
maximum of 1A.
24V
∼
outlet: To power any equipment at a voltage of 24V
∼
with a maximum consumption of
0,75A.
Auto-test outlet (TEST SEC.): 24V
∼
outlet for auto-test of security parts.
OPTION SELECTOR 1
Option No.
Lower position – OFF (default option)
Upper position – ON
1
Allows for reverse on opening
Does not allow for reverse on opening
2
Normal opening
Opening with sudden reverse (from 0 to 0.5
seconds, motor 1)
3
Does not close automatically Automatic
closure
4
Pre-flash disabled
Pre-flash enabled
5
The security edge close carries out its
normal function
The security contact close also activates the
closing button after the vehicle has passed
6
One motor operating
Two motors operating
7
Normal operating speed
Slow speed at end of operation according to
programming (after 2 seconds from start of
operation)
8
Start button causes stoppage on closure
Start button causes stoppage and reverse on
closure
9
Acoustic signal disabled
Acoustic signal enabled during door movement
OPTION SWITCH 2
Option No.
Lower position – OFF (default option)
Upper position – ON
1
No autotest carried out
This carries out the autotest for the security
close contact
2
No autotest carried out
This carries out the autotest for the security
open contact