background image

1257014-GB_v1.1 

STD-1EU / STD-2EU 

 

3

Stop (PARO): Contact normally closed. This detains the operation on standby for a new order. 

Where not used, turn option 5 on the input switch to ON. 

 
Open (ABR.): Contact normally open to open. If it is pressed while the door is closing, it will stop 

and open. 

 
Close (CER.): Contact normally open to close. If it is pressed while the door is closing, it

 

will not be 

triggered. 

 
Pedestrian (PEA.): Contact normally open for partial opening. This acts only with motor 1. 

 

Ends of run (FCC1 / FCA1 / FCC2 / FCA2): contacts normally closed to mechanically indicate the 

open and closed end of run. Where not used, turn option 6, 7, 8 or 9 on the input switch to ON. 
 

Security edge (BS.CE / BS.AB.): Resistive contact for resistive security edge. This acts on closing, 

causing stoppage and inversion. This acts on opening, causing stoppage and inversion of 1s. Where 
not used, turn option 3 or 4 on the input switch to ON. 

 

Security contact (S.CER / S.ABR): Contact normally closed, photocell or magnetic detector type. 
This acts on opening and closing, causing stoppage and inversion. Where not used, turn option 1 or 

2 on the input switch to ON. 

 

Garage light contact (LUZ GAR.): Voltage-free contact to activate an automatic light (max 100W to 
230V

). 

 

Flash light contact (DESTELLO): Voltage-free maintained contact to activate a Flash light (max 

250V / 12A) 
 
Electro-lock (ELECTRO): 12V

=

 output timed for 2 seconds to activate an electric latch of a 

maximum of 1A. 

 

24V

 outlet: To power any equipment at a voltage of 24V

 with a maximum consumption of 

0,75A. 

 

Auto-test outlet (TEST SEC.): 24V

 outlet for auto-test of security parts.  

 

OPTION SELECTOR 1 

Option No.

 

Lower position – OFF (default option)

 

Upper position – ON

 

Allows for reverse on opening 

Does not allow for reverse on opening 

Normal opening 

Opening with sudden reverse (from 0 to 0.5 
seconds, motor 1) 

Does not close automatically Automatic 

closure 

Pre-flash disabled 

Pre-flash enabled 

The security edge close carries out its 

normal function 

The security contact close also activates the 

closing button after the vehicle has passed 

One motor operating 

Two motors operating 

Normal operating speed 

Slow speed at end of operation according to 
programming (after 2 seconds from start of 

operation) 

Start button causes stoppage on closure 

Start button causes stoppage and reverse on 

closure 

Acoustic signal disabled 

Acoustic signal enabled during door movement 

 

OPTION SWITCH 2 

Option No. 

Lower position – OFF (default option)  

Upper position – ON 

1  

No autotest carried out 

This carries out the autotest for the security 

close contact  

2  

No autotest carried out 

This carries out the autotest for the security 

open contact 

Summary of Contents for STD-2EU

Page 1: ...ICS Panel supply 230V ac Power 3 4CV Optional cards Pluggable receiver card 2 channels 433 92 868 35 MHz and traffic light card Security device output 24V ac 0 75A and autotest Electro lock outlet 12V...

Page 2: ...Close motor 2 STANDARD 2 EU version 27 End of run Open motor 2 STANDARD 2 EU version 28 Common buttons 29 Pedestrian button NO 30 Start button NO 31 Close button NO 32 Common buttons 33 Stop button N...

Page 3: ...V Flash light contact DESTELLO Voltage free maintained contact to activate a Flash light max 250V 12A Electro lock ELECTRO 12V output timed for 2 seconds to activate an electric latch of a maximum of...

Page 4: ...ling Minimum Maximum Motor operating 3s 120s Wait for automatic close 3s 120s Gap between motors 0s 120s LIGHT INDICATORS Function Indicates Default status POWER Alimentation Normally on SEG Security...

Page 5: ...ps if the end of run has not been reached and the automatic standby timer begins When pressed for the fifth time the automatic standby timer stops and motor 2 is started to close When pressed for the...

Page 6: ...g the panel check that the door is in good mechanical condition correctly balanced and that it opens and closes correctly Install the manual unlocking device at a height lower than 1 8m Install any pe...

Page 7: ...ls on how to use the manual unlocking device must be provided by the manufacturer or the device installer Examine the installation frequently especially the cables springs and supports to detect signs...