background image

1257014-GB_v1.1 

STD-1EU / STD-2EU 

 

5

 
 
 

PROGRAMMING 

• If, during programming, a stoppage is made, the control panel will automatically exit 

programming for safety reasons. 

• Before starting any type of time programming, it is wise to have the corresponding options 

correctly selected (option switch and input switch). 
• Operations can be programmed indifferently using the “Test” / “Start” button or through a 

transmitter recorded on a pluggable radio card for control panels. 

 
Below are the most frequent programming operations: 

 

 

Programming with one door and automatic close 

Close the door with the limit switches (where applicable) duly connected and option 3 of the option 

switched to ON. 
Press the 

Programming 

button and the programming led will switch on. Use the 

TEST 

button to 

programme the run. First time it is pressed, it opens. The second time it is pressed (if it has not 
reached the end of run), it stops and the automatic standby timer begins. The third time it is 

pressed, it stops the automatic standby timer and closes. The fourth time it is pressed (if it has not 

reached the end of run), it stops. The fifth time it is pressed, stops the garage light timer and exit 
the programming mode. The programming led will switch off. 

 
 

Programming with 2 doors and automatic close 

Close the door with the limit switches (where applicable) duly connected and option 3 and 6 of the 

option switched to ON. 
Press the 

Programming 

button and the programming led will switch on. Use the 

TEST 

button to 

programme the run. When pressed for the first time, motor 1 is started. The second time it is 
pressed, motor 2 is started. When pressed for the third time, motor 1 stops (if the end of run has 

not been reached). When pressed for the fourth time, motor 2 stops (if the end of run has not been 

reached) and the automatic standby timer begins. When pressed for the fifth time, the automatic 
standby timer stops and motor 2 is started to close. When pressed for the sixth time, motor 1 is 

started to close. When pressed for the seventh time, motor 2 stops (if the end of run has not been 

reached). When pressed for the eighth time, motor 1 stops (if the end of run has not been reached). 
The ninth time it is pressed, stops the garage light timer and exit the programming mode. The 

programming led will switch off. 

 
 

Programming with 2 doors, automatic close and slow speed at the end of operations 

Close the door with the limit switches (where applicable) duly connected and option 3 and 7 of the 

option switched to ON. 

Press the 

Programming 

button and the programming led will switch on. Use the 

TEST 

button to 

programme the run. The first time it is pressed, motor 1 is started. The second time it is pressed, 
motor 2 is started. The third time it is pressed, the motor 1 opening function is slowed down. The 

fourth time it is pressed, the motor 2 opening function is slowed down. The fifth time it is pressed, 

motor 1 stops, if it has not reached the end of run. The sixth time it is pressed, motor 2 stops, if it 

has not reached the end of run, and the automatic standby timer begins. When pressed for the 
seventh time, the automatic standby timer stops and motor 2 is started to close. When pressed for 

the eighth time, motor 1 is started to close. When pressed for the ninth time the motor 2 closing 

operation is slowed down. When pressed for the tenth time the motor 1 closing operation is slowed 
down. The eleventh time it is pressed, motor 2 stops, if it has not reached the end of run. The 

twelfth time it is pressed, motor 1 stops, if it has not reached the end of run. The thirteenth time it 

is pressed, stops the garage light timer and exit the programming mode. The programming led will 
switch off. 

Summary of Contents for STD-2EU

Page 1: ...ICS Panel supply 230V ac Power 3 4CV Optional cards Pluggable receiver card 2 channels 433 92 868 35 MHz and traffic light card Security device output 24V ac 0 75A and autotest Electro lock outlet 12V...

Page 2: ...Close motor 2 STANDARD 2 EU version 27 End of run Open motor 2 STANDARD 2 EU version 28 Common buttons 29 Pedestrian button NO 30 Start button NO 31 Close button NO 32 Common buttons 33 Stop button N...

Page 3: ...V Flash light contact DESTELLO Voltage free maintained contact to activate a Flash light max 250V 12A Electro lock ELECTRO 12V output timed for 2 seconds to activate an electric latch of a maximum of...

Page 4: ...ling Minimum Maximum Motor operating 3s 120s Wait for automatic close 3s 120s Gap between motors 0s 120s LIGHT INDICATORS Function Indicates Default status POWER Alimentation Normally on SEG Security...

Page 5: ...ps if the end of run has not been reached and the automatic standby timer begins When pressed for the fifth time the automatic standby timer stops and motor 2 is started to close When pressed for the...

Page 6: ...g the panel check that the door is in good mechanical condition correctly balanced and that it opens and closes correctly Install the manual unlocking device at a height lower than 1 8m Install any pe...

Page 7: ...ls on how to use the manual unlocking device must be provided by the manufacturer or the device installer Examine the installation frequently especially the cables springs and supports to detect signs...