STD-1EU / STD-2EU 

 

4

Note: If the security contact is not connected (option 1 and/or 2 of the input switch at ON), you 

must have the option 1 and/or 2 (TEST SEG. CERRAR / TEST SEG. ABRIR) of the option switch 2 

at OFF.  

 

INPUT SWITCH 

Option No.  Lower position - OFF 

Upper position – ON (default option) 

Security Close contact connected 

Security Close contact not connected 

Security Open contact connected 

Security Open contact not connected 

Security Close edge connected 

Security Close edge not connected 

Security Open edge connected 

Security Open edge not connected 

Stop button connected 

Stop button not connected 

End of run close for motor 1 connected 

End of run close for motor 1 not connected 

End of run open for motor 1 connected 

End of run open for motor 1 not connected 

End of run close for motor 2 connected 

End of run close for motor 2 not connected 

End of run open for motor 2 connected 

End of run open for motor 2 not connected 

 
 

TIMERS 

Colour Controlling Minimum 

Maximum 

Blue Motor 

power  25%  100% 

 
 

TIMES 

Controlling Minimum 

Maximum 

Motor operating 

3s 

120s 

Wait for automatic close 

3s 

120s 

Gap between motors 

0s 

120s 

 
 
LIGHT INDICATORS 

Function Indicates 

Default 

status 

POWER Alimentation 

Normally 

on 

SEG. Security 

Normally 

off 

PARO 

Stop button 

Normally on 

ALT 

Open/close function 

Normally off 

CERRAR Close 

function Normally 

off 

ABRIR 

Open function 

Normally off 

PEAT 

Pedestrian function 

Normally off 

FCA M2 

End of run open for motor 2 

Normally on 

FCC M2 

End of run close for motor 2 

Normally on 

FCA M1 

End of run open for motor 1 

Normally on 

FCC M1 

End of run close for motor 1 

Normally on 

SEG.ABR.  Security Open edge 

Normally on 

SEG.CER.  Security Close edge 

Normally on 

 
 

SECURITY EDGE CONNECTION 

No. of security edges 

Open Close 

Connections 

- - 

Default 

option 

Turn option 3 on the input switch to OFF. 

Turn option 4 on the input switch to OFF. Cut off jumper BS.CE 

Turn option 3 on the input switch to OFF. 

Turn option 3 and 4 on the input switch to OFF. 

Turn option 3 and 4 on the input switch to OFF. Cut off jumper BS.CE. 

Turn option 3 on the input switch to OFF. Cut off jumper BS.AB. 

Turn option 3 and 4 on the input switch to OFF. Cut off jumper BS.AB. 

Turn option 3 and 4 on the input switch to OFF. Cut off jumper BS.CE. and BS.AB 

Summary of Contents for STD-2EU

Page 1: ...ICS Panel supply 230V ac Power 3 4CV Optional cards Pluggable receiver card 2 channels 433 92 868 35 MHz and traffic light card Security device output 24V ac 0 75A and autotest Electro lock outlet 12V...

Page 2: ...Close motor 2 STANDARD 2 EU version 27 End of run Open motor 2 STANDARD 2 EU version 28 Common buttons 29 Pedestrian button NO 30 Start button NO 31 Close button NO 32 Common buttons 33 Stop button N...

Page 3: ...V Flash light contact DESTELLO Voltage free maintained contact to activate a Flash light max 250V 12A Electro lock ELECTRO 12V output timed for 2 seconds to activate an electric latch of a maximum of...

Page 4: ...ling Minimum Maximum Motor operating 3s 120s Wait for automatic close 3s 120s Gap between motors 0s 120s LIGHT INDICATORS Function Indicates Default status POWER Alimentation Normally on SEG Security...

Page 5: ...ps if the end of run has not been reached and the automatic standby timer begins When pressed for the fifth time the automatic standby timer stops and motor 2 is started to close When pressed for the...

Page 6: ...g the panel check that the door is in good mechanical condition correctly balanced and that it opens and closes correctly Install the manual unlocking device at a height lower than 1 8m Install any pe...

Page 7: ...ls on how to use the manual unlocking device must be provided by the manufacturer or the device installer Examine the installation frequently especially the cables springs and supports to detect signs...

Reviews: