2
2
1
1
2
2
2
5
3
4
6
6
RX
RX
TX
TX
7
a
b
c
d
e
f
g
1113
750
311
85
85
119
S450H
ENGLISH
1 DESCRIPTION AND TECHNICAL SPECIFICATIONS
1.1 DIMENSIONS
a
Front fitting
b
Cover
c
Emergency release with key
d
Plastic cover for rear bracket
e
Rear bracket
f
Encoder
g
Spacer for opening mechanical stop
TECHNICAL
SPECIFICATIONS
CBAC
OPERATOR
SB
OPERATOR
Power supply (V dc)
24 - 36
Power consumption (W)
60 (nominal) - 288 (maximum)
Protection class
IP 55
Oil type
FAAC HP OIL
Operating temperature
-20°C +50°C
R.O.T. (24V)
Continuous at 55°C
Hydraulic lock
Installed
Not installed
Traction/thrust force
max (N)
5000 (E124) - 3600 (E024S)
Max. opening angle
See table 1
Max. leaf length (m)
2
3
Rod linear speed (Cm/s)
2,5 (E124) - 2,0 (E024S)
Effective rod stroke (mm)
311
Operator weight (kg)
7.1
6.9
2 PRESETTINGS
b
RX
Photocells (receiver)
(TRADITIONAL: 4 x 0.5 mm²; 2easy bus: 2 x 0.5 mm²)
b
TX
Photocells (transmitter)
(2 x 0.5 mm²)
c
Electronic control unit
(power supply 3 x 1.5 mm²)
d
Key-operated push-button (e.g. T11) (3 x 0.5 mm²)
e
Flashing lamp 24 V dc (2 x 1 mm²)
f
Opening mechanical stops*
g
Electric lock and closing mechanical stop
(2 x 1.5 mm)
3 INSTALLATION OF THE AUTOMATED SYSTEM
Following conditions have to be met to ensure safety and the
efficient operation of the automated system:
• The gate structure must be suitable for automation. Verify in
particular that it is sufficiently strong and stiff and that dimensions
and weight correspond to those stated in the technical
specifications.
• Verify the smooth and uniform movement of leaves, without
irregular friction during the whole travel.
• Verify the good condition of hinges.
• Verify the presence of mechanical limit switches.
• Remove any locks and bolts.
Carry out any metalwork operations before installing the
automated system.
Fig. 1
Fig. 2
The FAAC S450H automated system for swing-leaf gates consists
of an electrical pump and an hydraulic piston transmitting the
leaf movement, assembled in a single block.
The model with hydraulic lock can automate leaves up to 2 m.
It does not require the installation of electric locks and guaran-
tees that the leaf is mechanically locked when the motor is not
in operation. The model without hydraulic lock always needs
one or more electric locks to guarantee the leaf mechanical
lock.
The S450H automated systems have been designed
and built to automate swing-leaf gates. Avoid any other use
whatever.
Without encoder the automated system does not operate
correctly.
Fig. 3
Dimensions in millimeters
* CONSIDERING 40 bar (E124) 30 bar (E024) STATIC PRESSURE
ON PISTONE
** CONSIDERING A RANGE OF PUMP 1.5 lpm (E124) AND 1.2
lpm (E024S)
a
DISTANCE (m)
20 m
35 m
50 m
ø
MOTOR CABLE
2x2.5 mm²
2x4 mm²
2x6 mm²
ø
2 easy bus
ENCODER CABLE
2x0.5 mm² 2x0.5 mm² 2x0.5 mm²
www.metalines.com