Estate Slide E-SL 1200
J1—Terminal Board for Master Card (cont.)
Terminals (cont.)
4
-
“Opening Safety Device” This is a normally closed terminal where by any device (i.e. photocells, sensitive edge,
magnetic loops) which, if there is an obstacle in the area they protect during opening, reverses gate direction to clos-
ing.
If the opening safety devices are tripped when the gate is closed, they prevent the leaf movement.
IMPORTANT:
If a connection is not made from this terminal to one of the
-
(negative) terminals (i.e. 12, 13, 14,
15) gate opening will not commence
.
5
-
“Closing Safety Device” This is a normally closed terminal where by any device (i.e. photocells, sensitive edge,
magnetic loops) which, if there is an obstacle in the area they protect during closing, reverses gate direction to open-
ing.
If the closing safety devices are tripped when the gate is open, they prevent the leaf movement.
IMPORTANT:
If a connection is not made from this terminal to one of the—(negative) terminals (i.e. 12, 13, 14,
15) gate closing will not commence.
6
-
N/A
7, 8
-
“Positive 24 Voltage” Positive 24V for powering accessories that are run by 24V DC power (i.e. locks, safety
devices).
9
-
“Indicator Light” When used with terminal
11
, this terminal powers and operates the indicator light.
To avoid com-
promising correct operation of the system, do not exceed the indicated power (12V .5Wmax).
The indicator
light is lit during open, opening and blocked. The indicator is flashing during closing.
10
-
“Lamp” When used with terminal
11
, this terminal powers and operates the flashing lamp output.
To avoid com-
promising correct operation of the system, do not exceed the indicated power (12V 21Wmax).
11
-
“Positive 12 Voltage” This is a 12V terminal used to power the indicator light, lamp and devices controlled by
12V DC.
12, 13, 14 ,15
-
“Negatives” Interchangeable negative terminals for use with powered accessories, safety devices and
opening devices.
14.2