background image

Estate Slide E-SL 1200 

CE DECLARATION OF CONFORMITY OF MACHINES

 

(Directive 89/392/EEC, Annex II, Part B)

 

Manufacturer: FAAC S.p.A.

 

Address: Via Benini, 1 – 40069 Zola Predosa Bologna – Italy

 

Declares that: 740 A.K.A. Estate Slide 1800 (USA) mod operator

 

 

Is built to be integrated into a machine or to be assembled with other machinery to create a machine under the provisions of Directive 89/392/EEC, and 
subsequent amendments 91/368/EEC, 93/44/EEC.

 

 

Conforms to the essential safety requirements of the following EEC directives:

 

o

 

73/23/EEC and subsequent amendment 93/68/EEC, 89/336/EEC and subsequent amendment 92/31/EEC and 93/68/EEC.

 

o

 

And also declares the it is prohibited to put into service the machinery until the machine in which it will be integrated or of which it will 
become a component has been identified and declared as conforming to the conditions of Directive 89/392/EEC and subsequent amend-
ments assimilated under national laws under DPR #459 of July 24, 1996.

 

 

Bologna, January 1, 2002

 

 

Managing Director

 

A. Bassi

 

A

bassi

 

1.

 

Attention! To ensure the safety of people, it is important that you read all the following instructions. Incorrect installation or incorrect use of the product could 
cause serious harm to people.

 

2.

 

Carefully read the instructions before beginning to install the product.

 

3.

 

Store these instructions for future reference.

 

4.

 

This product was designed and built strictly for the use indicated in the documentation. Any other use, not expressly indicated here, could compromise the good 
condition/operation of the product and/or be a source of danger.

 

5.

 

FAAC declines all liability caused by improper use or use other than that for which automated system was intended.

 

6.

 

Do not install the equipment in an explosive atmosphere; the presence of inflammable gas or fumes is a serious danger to safety.

 

7.

 

The mechanical parts must conform to the provisions of Standards EN 12604 and EN 12605.

 

 

For non

-

EU countries, to obtain an adequate level of safety, the standards mentioned above must be observed, in addition to national legal regulations.

 

8.

 

FAAC is not responsible for failure to observe Good Technique in the construction of the closing elements to be motorized, of for any deformation that may occur 
during use.

 

9.

 

The installation must conform to Standards EN 12453 and EN 12445.

 

 

The safety level of the automated system must be C+D.

 

10.

 

Before attempting any job on the system, cut out electrical power and disconnect the batteries.

 

11.

 

The main power supply of the automated system must be fitted with an all

-

pole switch with contact opening distance of 3 mm or greater. Use of a 6A thermal 

breaker will all

-

pole circuit break is recommended.

 

12.

 

Make sure that a differential switch with threshold of 0.03 A is fitted upstream of the system.

 

13.

 

Make sure that the earthing system is perfectly constructed, and connect metal parts of the means of the closure to it.

 

14.

 

The automated system is supplied with an intrinsic anti

-

crushing safety device consisting of a torque control. Nevertheless, its tripping threshold must be checked as 

specified in the Standards indicated at point 10.

 

15.

 

The safety devices (EN 12978 standard) protect any danger areas against mechanical movement risks, such as crushing, dragging, and shearing.

 

16.

 

Use of at least one indicator

-

light (e.g. FAACLIGHT 12VDC) is recommended for every system, as well as a warning sign adequately secured to the frame structure, in 

addition to the devices mentioned at point “15”.

 

17.

 

FAAC declines all liability as concerns safety and efficient operation of the automated system, is system components not produced by FAAC are used.

 

18.

 

For maintenance, strictly use original parts by FAAC.

 

19.

 

Do not in any way modify the components of the automated system.

 

20.

 

The installer shall supply all information concerning manual operation of the system in case of an emergency, and shall hand over to the user the warnings hand-
book supplied with the product.

 

21.

 

Do not allow children or adults to stay near the product while it is operating.

 

22.

 

Keep remote controls or other pulse generators away from children, to prevent the automated system from being activated involuntarily.

 

23.

 

Transit through the leaves is allowed only when the gate is fully open.

 

24.

 

The user must not attempt any kind of repair or direct action whatever and contact qualified personnel only.

 

25.

 

Do not short

-

circuit the poles of the batteries and do not try to recharge the batteries with power supply units other than Master or Slave cards.

 

26.

 

Do not throw exhausted batteries into containers for other waste but dispose them in the appropriate containers to enable them to be recycled. 

 

27.

 

Anything not expressly specified in these instructions is not permitted.

 

Warnings for the Installer

 

General Safety Obligations

 

Summary of Contents for Estate Slide E-SL 1200 Series

Page 1: ...202 Series Manufactured by WARNING Read all instructions before beginning installation or use of this gate opener This operator exerts a high level of force Exercise caution at all times and stay clea...

Page 2: ...EN 12453 and EN 12445 The safety level of the automated system must be C D 10 Before attempting any job on the system cut out electrical power and disconnect the batteries 11 The main power supply of...

Page 3: ...ro mechanical linear operator powered by a 12V DC battery coupled with a control board recharg ing the battery The MASTER card can be programmed and is used to set the following function logics work t...

Page 4: ...e Operator and Limits 6 1 4 Control Board Layout 7 1 Power 8 1 Control Board Pre Learning Preparations 9 1 One Touch EZ Programming 10 1 Programing Gate Movement Variables i e auto close speed force d...

Page 5: ...ch full cycle Operating ambient temperature 4 to 131 F Operator weight lbs 4 85 Protection Class IP 44 Gate leaf max length ft Up to 12 Gate leaf max weight lbs Up to 550 Operator overall dimensions L...

Page 6: ...IMPORTANT Preliminary Checks To ensure safety and an efficiently operating automated system make sure the following conditions are observed The gate and post must be suitable for being automated Chec...

Page 7: ...determined by distance be tween transformer power supply and the control box If the gate is more than 1000 from an a c power supply then an alternate power will be necessary to charge your battery Dep...

Page 8: ...g the battery into the control board fig 1 For charging purposes it is not necessary to hook the receiver to the battery or control board 2 Insert the wires from the supplied AC transformer into the t...

Page 9: ...tive door by turning the slotted lock with a coin or large flat head screw driver 2 Take the supplied key located inside the door fit it in the release system and turn it clockwise un til it reaches t...

Page 10: ...plate 2 The foundation plate must be located as shown in example A right closing or example B left closing to ensure the rack and pinion mesh correctly 3 Secure the foundation plate to the floor usin...

Page 11: ...nections allow the cables to project by about 8 inches from the hole of the foundation plate Operator Installation 1 Position the operator on the plate using the supplied screws as shown below 2 Secur...

Page 12: ...ece of rack as shown below to synchronize the teeth of the two elements 5 More the gate manually and carry out the securing operations as far as the first element proceeding until the gate is fully co...

Page 13: ...Chapter 10 3 Manually take the gate to the open position but allow a space of 2 cm from the travel limit mechanical stop position Slide the magnet on the rack until you see that LED 1 on the control...

Page 14: ...r surge damage be covered under warranty Always separate power from control and safety cables push buttons receivers photocells etc To avoid any electri cal noise use separate sheaths or a shielded ca...

Page 15: ...nsformer plug the battery into the control board The clear plastic clip gets clipped into J4 with the clip side on the left The other side of the battery wire has a clear plastic disconnect that slide...

Page 16: ...and 5 to one of the negative terminals terminals 12 13 14 or 15 We recommend that these jumpers are later replaced with safety devices after learning is complete 2 Connect the power last First connec...

Page 17: ...ion LEDs A B C D E in picture are lit steadily briefly press about 1 second the P2 button The operator or operators start the opening maneuver and the function LEDs begin flashing Wait for the operato...

Page 18: ...ntrols A Switches between Function Logics Function Logics are sets of actions that will occur when an accessory ter minal connection is made or disrupted Each set of actions is designed to give differ...

Page 19: ...AP Stepped Automatic is very similar to automatic A but has a higher amount of safety It has an increased amount of motion stop points 4 EP Stepped Semi automatic is designed to function similar to a...

Page 20: ...rection after interrup tion Opening No effect Reverses direction of motion No effect Stopped in mid cycle Closes the leaf No effect Logic S Logic S safety is designed for higher control and accelerate...

Page 21: ...ion after interruption No effect Stopped in mid cycle Closes the leaf No effect Logic EP Logic EP stepped semi automatic is designed to function similar to a garage door opener At full open the gate d...

Page 22: ...Programming Receiver White Connector Red White Green Jumper Wire Antenna Green White Red Programming 1 Press and release Learn 1 2 Learn Light turns On 3 Press and hold remote button 4 Learn light bl...

Page 23: ...g and or closing pulse for both gate leaves if there is only one leaf it will control the one leaf 2 Single Leaf Open Close Function This is a normally open terminal where by any device i e push butto...

Page 24: ...en they prevent the leaf movement IMPORTANT If a connection is not made from this terminal to one of the negative terminals i e 12 13 14 15 gate closing will not commence 6 N A 7 8 Positive 24 Voltage...

Page 25: ...a tus check will stay active for 5 minutes and then the board returns to all LEDs Off Warning When you access the input status function all accessories are powered even with the gate idle P1 is active...

Page 26: ...ct and crushing Closing Safety Devices They operate only during the gate closing movement and therefore are suitable for protecting the closing zone against the risk of impact Opening Closing Safety D...

Page 27: ...nection of 2 pairs of photocells for closing Connection of 1 pair of photocells for opening Connection of 1 pair of photocells for closing Connection of a pair of closing photocells one for opening an...

Page 28: ...equired to e mail digital photos to the technician This is done in your best interest to save unnecessary shipping expenses and time lost Many times we can come up with solutions to issues by seeing p...

Reviews: